VACON NXP Common DC Bus Brake Chopper Unit 136G2932

VACON NXP Common DC Bus Brake Chopper Unit 37 kW 380-500V IP21 - 136G2932

Send inquiry Order code: 136G2932
(You save )
Brand
VACON
SKU:
136G2932
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
37
Rated current (A):
72
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR07
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB00725-A2T08SV-A1A2000000

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 136G2932 and type code NXB00725-A2T08SV-A1A2000000 is a 37 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It is rated 72 A continuous output current and meets EMC category C4.

Key specifications

Order code136G2932
Type codeNXB00725-A2T08SV-A1A2000000
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power37 kW
Power, high overload30 kW
Rated current72 A
Current, high overload61 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP21/NEMA1
Frame sizeFR07
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)591 x 237 x 257 mm
Net weight35 kg
EAN5710108593599

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current007272 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR07Frame 07
Motor Power Low Overload [kW]3737
Motor Power High Overload [kW]3030
Dimensions WxHxD [mm]237X591X257237X591X257
Continuous Current (NO) [A]7272
Continuous Current (HO) [A]6161

Typical applications

At 37 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • For heavy-duty use with high overload the rating is 30 kW / 61 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136G2932 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 136G2222

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 37 kW 380-500V IP21 - 136G2222

The VACON NXP Common DC Bus brake chopper unit with order code 136G2222 and type code NXB00725-A2T08SV-A1A3000000+QGLM+FL23+DLDE is a 37 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 136G8167

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 37 kW 380-500V IP21 - 136G8167

The VACON NXP Common DC Bus brake chopper unit with order code 136G8167 and type code NXB00725-A2T08SV-A1A200D6E9+QGLM+FL21+DLSE is a 37 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 137H9361

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137H9361

The VACON NXP Common DC Bus brake chopper unit with order code 137H9361 and type code NXB00725-G2T08SV-A1A200E900+QGLM+GADN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 137U4852

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U4852

The VACON NXP Common DC Bus brake chopper unit with order code 137U4852 and type code NXB00045-A2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137G6229

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137G6229

The VACON NXP Common DC Bus brake chopper unit with order code 137G6229 and type code NXB00725-A2T08SV-A1A20000E6 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...