  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Active Front End Unit 310 kW 380-500V IP00 - 136N4703
  • VACON NXP Common DC Bus Active Front End Unit 136N4703
VACON NXP Common DC Bus Active Front End Unit 136N4703

VACON NXP Common DC Bus Active Front End Unit 310 kW 380-500V IP00 - 136N4703

Send inquiry Order code: 136N4703
(You save )
Brand
VACON
SKU:
136N4703
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
310
Rated current (A):
385
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI10
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXA03855-G0T02SG-A1A2B500EC+FL26+DLCN

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 136N4703 and type code NXA03855-G0T02SG-A1A2B500EC+FL26+DLCN is a 310 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It is rated 385 A continuous output current and meets EMC category C4.

Key specifications

Order code136N4703
Type codeNXA03855-G0T02SG-A1A2B500EC+FL26+DLCN
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power310 kW
Rated current385 A
Current, high overload300 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI10
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1032 x 239 x 552 mm
Net weight100 kg
EAN5710108925703

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0385385 Amp
Control KeypadGGraphical panel
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CB53RO(NO)
Option Slot D00No board
Option Slot EECEtherCAT
Firmware language package+FL26UK,RU,CN;Others
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLCNChinese
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI10Frame 10 INU
Motor Power Low Overload [kW]310310
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1032X552239X1032X552
Continuous Current (NO) [A]456456
Continuous Current (HO) [A]300300

Typical applications

At 310 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: 3RO(NO); slot E: EtherCAT.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136N4703 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 136X2791

VACON 

VACON NXP Common DC Bus Active Front End Unit 310 kW 380-500V IP00 - 136X2791

The VACON NXP Common DC Bus active front end unit with order code 136X2791 and type code NXA03855-A0T02SG-A1A2D7BHE9+GRID+ARFIF106 is a 310 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136U7482

VACON 

VACON NXP Common DC Bus Active Front End Unit 310 kW 380-500V IP00 - 136U7482

The VACON NXP Common DC Bus active front end unit with order code 136U7482 and type code NXA03855-G0T02SG-A1A2000000+FL26+DLCN is a 310 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136X3802

VACON 

VACON NXP Common DC Bus Active Front End Unit 310 kW 380-500V IP00 - 136X3802

The VACON NXP Common DC Bus active front end unit with order code 136X3802 and type code NXA03855-A0T02SG-A1A2D7B5E9+GRID+ARFIF106 is a 310 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N6690

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N6690

The VACON NXP Common DC Bus active front end unit with order code 137N6690 and type code NXA04605-G0T02SG-A1A2B500E2+GSNT+EMAR+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137X2196

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137X2196

The VACON NXP Common DC Bus active front end unit with order code 137X2196 and type code NXA04605-A0T02SG-A1A2D700EC+GRID+ARFIF106+DLIT is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...