  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132L5817
  • VACON NXP Common DC Bus Active Front End Unit 132L5817
VACON NXP Common DC Bus Active Front End Unit 132L5817

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132L5817

Send inquiry Order code: 132L5817
(You save )
Brand
VACON
SKU:
132L5817
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
259
Rated current (A):
385
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA03855-A0T02SG-A1A2D700CP+FL23+GRID+ARFIF106+DLDE

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 132L5817 and type code NXA03855-A0T02SG-A1A2D700CP+FL23+GRID+ARFIF106+DLDE is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It is rated 385 A continuous output current and meets EMC category C4.

Key specifications

Order code132L5817
Type codeNXA03855-A0T02SG-A1A2D700CP+FL23+GRID+ARFIF106+DLDE
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power259 kW
Rated current385 A
Current, high overload300 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 239 x 552 mm
Net weight100 kg
EAN5714853453382

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0385385 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CD7Line voltage meas.
Option Slot D00No board
Option Slot ECPPROFINET
Firmware language package+FL23UK,NL,DE,FR,ITWestEurII
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLDEGerman
System Firmware+FNP02System software NXP
Software license+GRID+UGRD & +GRDC
Application+ARFIF106Grid Conv with codes NXA,NXI
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI10Frame 10 INU
Motor Power Low Overload [kW]259259
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X552239X1030X552
Continuous Current (NO) [A]385385
Continuous Current (HO) [A]300300

Typical applications

At 259 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: Line voltage meas.; slot E: PROFINET.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 132L5817 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 132H8391

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132H8391

The VACON NXP Common DC Bus active front end unit with order code 132H8391 and type code NXA03855-A0T02SG-A1A2B50000+GSNT+GALR+LPC2+SPXE is a 259 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 132N1197

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132N1197

The VACON NXP Common DC Bus active front end unit with order code 132N1197 and type code NXA03855-G0T02SG-A8A2000000+FL26 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132N2055

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132N2055

The VACON NXP Common DC Bus active front end unit with order code 132N2055 and type code NXA03855-G0T02SG-A8A2000000 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132X3265

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132X3265

The VACON NXP Common DC Bus active front end unit with order code 132X3265 and type code NXA03855-A0T02SG-A1A2000000+ARFIFF02V141 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136L9239

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 136L9239

The VACON NXP Common DC Bus active front end unit with order code 136L9239 and type code NXA03855-A0T02SG-A1A2000000 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...