Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
45
Mains voltage:
380-500 V
Enclosure:
IP54
Frame size:
FR06
EMC category:
C4
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXB00455-G5T08SV-A1A200E900+FL26

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 137G7983 and type code NXB00455-G5T08SV-A1A200E900+FL26 is a 2 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06 configuration. It is rated 45 A continuous output current and meets EMC category C4.

Key specifications

Order code137G7983
Type codeNXB00455-G5T08SV-A1A200E900+FL26
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current45 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP54/NEMA12
Frame sizeFR06
EMC categoryC4
Brake chopperNot included
Control panelGraphical Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Net weight16 kg
EAN5715253342580

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current004545 Amp
Control KeypadGGraphical panel
Enclosure5IP54/NEMA12
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot DE92-port ethernet
Option Slot E00No board
Firmware language package+FL26UK,RU,CN;Others
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR06Frame 06
Motor Power Low Overload [kW]2X282X28
Motor Power High Overload [kW]--
Continuous Current (NO) [A]2X452X45
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot D: 2-port ethernet.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 137G7983 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 137G4112

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP54 - 137G4112

The VACON NXP Common DC Bus brake chopper unit with order code 137G4112 and type code NXB00455-G5T08SV-A1A200E900 is a 2 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132H2358

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132H2358

The VACON NXP Common DC Bus brake chopper unit with order code 132H2358 and type code NXB05205-A0T08SG-A1A20000E9+FL23+DLNL is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132H2499

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H2499

The VACON NXP Common DC Bus brake chopper unit with order code 132H2499 and type code NXB00385-A2T08SV-A8A20000CI is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132H5087

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H5087

The VACON NXP Common DC Bus brake chopper unit with order code 132H5087 and type code NXB00725-A2T08SV-A8A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132N2779

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132N2779

The VACON NXP Common DC Bus brake chopper unit with order code 132N2779 and type code NXB03005-A0T08SG-A8B1000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...