  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136Z8047
  • VACON NXP Common DC Bus Brake Chopper Unit 136Z8047
VACON NXP Common DC Bus Brake Chopper Unit 136Z8047

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136Z8047

Send inquiry Order code: 136Z8047
(You save )
Brand
VACON
SKU:
136Z8047
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
31
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR06
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB00315-A2T08SV-A1A2000000

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 136Z8047 and type code NXB00315-A2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It is rated 31 A continuous output current and meets EMC category C4.

Key specifications

Order code136Z8047
Type codeNXB00315-A2T08SV-A1A2000000
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Power, high overload11 kW
Rated current31 A
Current, high overload23 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP21/NEMA1
Frame sizeFR06
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)557 x 195 x 237 mm
Net weight18.5 kg
EAN5714853271153

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current003131 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR06Frame 06
Motor Power Low Overload [kW]2X202X20
Motor Power High Overload [kW]1111
Dimensions WxHxD [mm]195X557X237195X557X237
Continuous Current (NO) [A]2X312X31
Continuous Current (HO) [A]2323

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • For heavy-duty use with high overload the rating is 11 kW / 23 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136Z8047 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 136X8704

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136X8704

The VACON NXP Common DC Bus brake chopper unit with order code 136X8704 and type code NXB00385-G2T08SV-A1A2000000+FL26+DLCN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Brake Chopper Unit 137G3344

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137G3344

The VACON NXP Common DC Bus brake chopper unit with order code 137G3344 and type code NXB00725-A2T08SV-A1A30000E9+DNOT is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 137L1475

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L1475

The VACON NXP Common DC Bus brake chopper unit with order code 137L1475 and type code NXB00725-A2T08SV-0000000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137L8042

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L8042

The VACON NXP Common DC Bus brake chopper unit with order code 137L8042 and type code NXB00725-A2T08SV-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137U5482

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U5482

The VACON NXP Common DC Bus brake chopper unit with order code 137U5482 and type code NXB00455-A2T08SV-A9A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...