  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 380-500 V
  • VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136U2966
  • VACON NXP Common DC Bus Brake Chopper Unit 136U2966
VACON NXP Common DC Bus Brake Chopper Unit 136U2966

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136U2966

Send inquiry Order code: 136U2966
(You save )
Brand
VACON
SKU:
136U2966
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
2
Rated current (A):
460
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FI10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXB04605-A0T08SG-A1A2000000+FL24+DLPL

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus brake chopper unit with order code 136U2966 and type code NXB04605-A0T08SG-A1A2000000+FL24+DLPL is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It is rated 460 A continuous output current and meets EMC category C4.

Key specifications

Order code136U2966
Type codeNXB04605-A0T08SG-A1A2000000+FL24+DLPL
SeriesVACON® NXP Common DC Bus
Product typeBrake Chopper Unit
Rated power2 kW
Rated current460 A
Mains voltage380 – 500 Vac (465-800 Vdc)
EnclosureIP00
Frame sizeFI10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Net weight100 kg
EAN5714853009862

Type code configuration

OptionCodeSelection
Product GroupNXBBrake Chopper Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0460460 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification8BCU Brake chopper unit
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL24UK,EE,PL,CZ,DE;CentEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLPLPolish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ABFIFF01Brake Chopper Unit NXB
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI10Frame 10 INU
Motor Power Low Overload [kW]2X2932X293
Motor Power High Overload [kW]--
Continuous Current (NO) [A]2X4602X460
Continuous Current (HO) [A]--

Typical applications

At 2 kW, this brake chopper unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • A brake chopper unit dissipates excess DC bus energy in an external braking resistor during braking.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136U2966 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Brake Chopper Unit 137G0359

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137G0359

The VACON NXP Common DC Bus brake chopper unit with order code 137G0359 and type code NXB03855-A0T08SG-A8A20000E3+GAAB is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137G2985

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137G2985

The VACON NXP Common DC Bus brake chopper unit with order code 137G2985 and type code NXB02055-A0T08SG-A1A20000E9+GSNT+DLFR+LPC2+SPXE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137G8609

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137G8609

The VACON NXP Common DC Bus brake chopper unit with order code 137G8609 and type code NXB04605-A0T08SG-A1A30000E6 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137X2273

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137X2273

The VACON NXP Common DC Bus brake chopper unit with order code 137X2273 and type code NXB01685-A0T08SG-A1A200CI00+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 132N7685

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132N7685

The VACON NXP Common DC Bus brake chopper unit with order code 132N7685 and type code NXB01685-A0T08SG-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...