VACON NXP Common DC Bus Active Front End Unit 136X1384

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 136X1384

Send inquiry Order code: 136X1384
(You save )
Brand
VACON
SKU:
136X1384
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
197
Rated current (A):
170
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FI09
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA01706-A0T02SG-A1A2000000

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 136X1384 and type code NXA01706-A0T02SG-A1A2000000 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It is rated 170 A continuous output current and meets EMC category C4.

Key specifications

Order code136X1384
Type codeNXA01706-A0T02SG-A1A2000000
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power197 kW
Rated current170 A
Current, high overload144 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI09
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 239 x 372 mm
Net weight67 kg
EAN5714853095384

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0170170 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI09Frame 09 INU
Motor Power Low Overload [kW]197197
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X372239X1030X372
Continuous Current (NO) [A]200200
Continuous Current (HO) [A]144144

Typical applications

At 197 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC).

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136X1384 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 136X2334

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 136X2334

The VACON NXP Common DC Bus active front end unit with order code 136X2334 and type code NXA01706-A0T02SG-A1A2000000+FL25+LS60 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132X5018

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 132X5018

The VACON NXP Common DC Bus active front end unit with order code 132X5018 and type code NXA01706-G0T02SG-A1A2000000+DLCN is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132H2871

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 132H2871

The VACON NXP Common DC Bus active front end unit with order code 132H2871 and type code NXA01706-A0T02SG-A1A2B50000+GSNT+SPXC is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137G0007

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 137G0007

The VACON NXP Common DC Bus active front end unit with order code 137G0007 and type code NXA01706-A0T02SG-A1AF00D2C4 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136X7400

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 136X7400

The VACON NXP Common DC Bus active front end unit with order code 136X7400 and type code NXA01706-A0T02SG-A1A2D7E900+GRID+ARFIF106 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame...