  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus
  • VACON NXP Common DC Bus 525-690 V
  • VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136U5346
  • VACON NXP Common DC Bus Active Front End Unit 136U5346
VACON NXP Common DC Bus Active Front End Unit 136U5346

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136U5346

Send inquiry Order code: 136U5346
(You save )
Brand
VACON
SKU:
136U5346
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
145
Rated current (A):
125
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FI09
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA01256-A0T02SG-A1A200B5E9

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 136U5346 and type code NXA01256-A0T02SG-A1A200B5E9 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It is rated 125 A continuous output current and meets EMC category C4.

Key specifications

Order code136U5346
Type codeNXA01256-A0T02SG-A1A200B5E9
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power145 kW
Rated current125 A
Current, high overload100 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI09
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 239 x 372 mm
Net weight67 kg
EAN5714853033492

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0125125 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot DB53RO(NO)
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI09Frame 09 INU
Motor Power Low Overload [kW]145145
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]239X1030X372239X1030X372
Continuous Current (NO) [A]147147
Continuous Current (HO) [A]100100

Typical applications

At 145 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot D: 3RO(NO); slot E: 2-port ethernet.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 136U5346 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 132H3683

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 132H3683

The VACON NXP Common DC Bus active front end unit with order code 132H3683 and type code NXA01256-A0T02SG-A1A2D700EA+UGRD+ARFIF106+LS60 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 136N8483

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136N8483

The VACON NXP Common DC Bus active front end unit with order code 136N8483 and type code NXA01256-A0T02SG-A1A2000000 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136L0936

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136L0936

The VACON NXP Common DC Bus active front end unit with order code 136L0936 and type code NXA01256-A0T02SG-A1A20000E9 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136Z8265

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136Z8265

The VACON NXP Common DC Bus active front end unit with order code 136Z8265 and type code NXA01256-A0T02SG-A1A2D700E9 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136X3878

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136X3878

The VACON NXP Common DC Bus active front end unit with order code 136X3878 and type code NXA01256-G0T02SG-A1A2D700E9+FL25+GRID+ARFIF106+LS60 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure,...