VACON NXP Common DC Bus Active Front End Unit 137U1846

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137U1846

Send inquiry Order code: 137U1846
(You save )
Brand
VACON
SKU:
137U1846
UPC:
Condition:
New
Series:
VACON NXP Common DC Bus
Power (kW):
1194
Rated current (A):
1030
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FI13
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXA10306-A0T02SG-A1A200D2E3

Adding to cart… The item has been added

Description

The VACON NXP Common DC Bus active front end unit with order code 137U1846 and type code NXA10306-A0T02SG-A1A200D2E3 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13 configuration. It is rated 1030 A continuous output current and meets EMC category C4.

Key specifications

Order code137U1846
Type codeNXA10306-A0T02SG-A1A200D2E3
SeriesVACON® NXP Common DC Bus
Product typeActive Front End Unit
Rated power1194 kW
Rated current1030 A
Current, high overload920 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFI13
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1030 x 708 x 553 mm
Net weight292 kg
EAN5715253701820

Type code configuration

OptionCodeSelection
Product GroupNXAActive Front-End Unit
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current10301030 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical Modification2AFE module w/o LCL
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot EE3PROFIBUS DP
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+ARFIFF02AFE application NXA,NXI,NXP
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFI13Frame 13 INU
Motor Power Low Overload [kW]11941194
Motor Power High Overload [kW]--
Dimensions WxHxD [mm]708X1030X553708X1030X553
Continuous Current (NO) [A]10301030
Continuous Current (HO) [A]920920

Typical applications

At 1194 kW, this active front end unit is typically used for multi-drive systems that share one DC bus, such as paper machines, cranes, test benches and process lines.

Configuration notes

  • An active front-end (AFE) unit feeds the common DC bus from the mains and returns braking energy to the grid, with low harmonic distortion.
  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot D: SysBus(1fiber), CAN-MonBus; slot E: PROFIBUS DP.

About the VACON NXP Common DC Bus series

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

Need this exact configuration or an alternative? Send us the order code 137U1846 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Common DC Bus Active Front End Unit 132H0605

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 132H0605

The VACON NXP Common DC Bus active front end unit with order code 132H0605 and type code NXA10306-A0T02SG-A1A2B50000+GSNT+GAKR+SPXC is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136U3420

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136U3420

The VACON NXP Common DC Bus active front end unit with order code 136U3420 and type code NXA10306-G0T02SG-A1A2000000+FL26+DLCN is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 132X6472

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 132X6472

The VACON NXP Common DC Bus active front end unit with order code 132X6472 and type code NXA10306-A0T02SG-A1A20000CI is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136X6768

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136X6768

The VACON NXP Common DC Bus active front end unit with order code 136X6768 and type code NXA10306-A0T02SG-A8A2B1D200 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136X6668

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136X6668

The VACON NXP Common DC Bus active front end unit with order code 136X6668 and type code NXA10306-A0T02SG-A1A2D7B5EC+GRDC+ARFIF106+LS60 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure,...