VACON NXP Air Cooled AC Drive 132H7008

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP54 - 132H7008

Send inquiry Order code: 132H7008
(You save )
Brand
VACON
SKU:
132H7008
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
90
Rated current (A):
100
Mains voltage:
525-690 V
Enclosure:
IP54
Frame size:
FR08
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP01006-A5T0SSV-A1AF0000E9+QGLM+FL24+DPAP+DLCZ

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 132H7008 and type code NXP01006-A5T0SSV-A1AF0000E9+QGLM+FL24+DPAP+DLCZ is a 90 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR08 configuration. It is rated 100 A continuous output current and meets EMC category C4.

Key specifications

Order code132H7008
Type codeNXP01006-A5T0SSV-A1AF0000E9+QGLM+FL24+DPAP+DLCZ
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power90 kW
Power, high overload75 kW
Rated current100 A
Current, high overload80 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP54/NEMA12
Frame sizeFR08
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)758 x 288 x 344 mm
Net weight58 kg
EAN5714853360864

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0100100 Amp
Control KeypadAAlpha-numeric display
Enclosure5IP54/NEMA12
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLMMetric conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot C00No board
Option Slot D00No board
Option Slot EE92-port ethernet
Firmware language package+FL24UK,EE,PL,CZ,DE;CentEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLCZCzech
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR08Frame 08
Motor Power Low Overload [kW]9090
Motor Power High Overload [kW]7575
Dimensions WxHxD [mm]288X758X344288X758X344
Continuous Current (NO) [A]100100
Continuous Current (HO) [A]8080
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 90 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 75 kW / 80 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot E: 2-port ethernet.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 132H7008 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137L0932

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP54 - 137L0932

The VACON NXP Air Cooled AC Drive with order code 137L0932 and type code NXP01006-A5T0SSV-A1A2B20000+FL21+DPAP is a 90 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR08 configuration. It...
VACON NXP Air Cooled AC Drive 132X4407

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP54 - 132X4407

The VACON NXP Air Cooled AC Drive with order code 132X4407 and type code NXP01006-A5T0SSV-A1A3000000+QGLM is a 90 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR08 configuration. It is...
VACON NXP Air Cooled AC Drive 136L6755

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP54 - 136L6755

The VACON NXP Air Cooled AC Drive with order code 136L6755 and type code NXP01006-F5T0SSV-A1A2000000+QGLM+DPAP+DLIT is a 90 kW (125 HP), three-phase 525-690 V supply, IP54 enclosure, frame FR08...
VACON NXP Air Cooled AC Drive 137N3740

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP54 - 137N3740

The VACON NXP Air Cooled AC Drive with order code 137N3740 and type code NXP01006-A5L0SSV-A1AFBHBHE5 is a 90 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR08 configuration. It is rated...
VACON NXP Air Cooled AC Drive 132L4730

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP54 - 132L4730

The VACON NXP Air Cooled AC Drive with order code 132L4730 and type code NXP01006-A5T0SSV-A1A2000000 is a 90 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR08 configuration. It is rated...