  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 525-690 V
  • VACON NXP Air Cooled AC Drive 90 kW 525-690V IP21 - 137H3530
  • VACON NXP Air Cooled AC Drive 137H3530
VACON NXP Air Cooled AC Drive 137H3530

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP21 - 137H3530

Send inquiry Order code: 137H3530
(You save )
Brand
VACON
SKU:
137H3530
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
90
Rated current (A):
100
Mains voltage:
525-690 V
Enclosure:
IP21
Frame size:
FR08
EMC category:
C3
Brake chopper:
No
Control panel:
Graphical Keypad
Type code:
NXP01006-G2L0SSV-A1A20000E5+QGLM+FL25+DPAP+DLES

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137H3530 and type code NXP01006-G2L0SSV-A1A20000E5+QGLM+FL25+DPAP+DLES is a 90 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration. It is rated 100 A continuous output current and meets EMC category C3.

Key specifications

Order code137H3530
Type codeNXP01006-G2L0SSV-A1A20000E5+QGLM+FL25+DPAP+DLES
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power90 kW
Power, high overload75 kW
Rated current100 A
Current, high overload80 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR08
EMC categoryC3
RFI filterClass A2
Brake chopperNot included
Control panelGraphical Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)758 x 288 x 344 mm
Net weight58 kg
EAN5715253402499

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0100100 Amp
Control KeypadGGraphical panel
Enclosure2IP21/NEMA1
EMC emission levelsLIEC61800-3, 2. environment
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLMMetric conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot EE5PROFIBUS DP with Sub-D9
Firmware language package+FL25US,FR,ES,PT;Americas
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLESSpanish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR08Frame 08
Motor Power Low Overload [kW]9090
Motor Power High Overload [kW]7575
Dimensions WxHxD [mm]288X758X344288X758X344
Continuous Current (NO) [A]100100
Continuous Current (HO) [A]8080

Typical applications

At 90 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C3 is intended for industrial (second environment) networks.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 75 kW / 80 A.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot E: PROFIBUS DP with Sub-D9.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137H3530 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137L0055

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP21 - 137L0055

The VACON NXP Air Cooled AC Drive with order code 137L0055 and type code NXP01006-A2T1SSV-A1AF0000E5+FL21+DPAP is a 90 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Air Cooled AC Drive 137L8668

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP21 - 137L8668

The VACON NXP Air Cooled AC Drive with order code 137L8668 and type code NXP01006-A2T0SSV-A1A3000000+QGLM+FL23+DPAP+DLDE is a 90 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08...
VACON NXP Air Cooled AC Drive 136F9992

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP21 - 136F9992

The VACON NXP Air Cooled AC Drive with order code 136F9992 and type code NXP01006-A2T1SSV-A8A3A5B200 is a 90 kW (125 HP), three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration. It is...
VACON NXP Air Cooled AC Drive 132X5577

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP21 - 132X5577

The VACON NXP Air Cooled AC Drive with order code 132X5577 and type code NXP01006-G2L0SSV-A1AFB500E5 is a 90 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration. It is rated...
VACON NXP Air Cooled AC Drive 132X6987

VACON 

VACON NXP Air Cooled AC Drive 90 kW 525-690V IP21 - 132X6987

The VACON NXP Air Cooled AC Drive with order code 132X6987 and type code NXP01006-A2T0BSV-A8B5B1BHE9+FL21+DCD3+ADFIF101+LPC2+SPXE is a 90 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08...