VACON NXP Air Cooled AC Drive 136U1861

VACON NXP Air Cooled AC Drive 75 kW 230V IP54 - 136U1861

Send inquiry Order code: 136U1861
(You save )
Brand
VACON
SKU:
136U1861
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
75
Power (HP):
100
Rated current (A):
261
Mains voltage:
230 V
Enclosure:
IP54
Frame size:
FR09
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP02612-A5T0SSG-A1A200D200+QGLM+APFIFF09+DPAP+DLES

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 136U1861 and type code NXP02612-A5T0SSG-A1A200D200+QGLM+APFIFF09+DPAP+DLES is a 75 kW (100 HP), three-phase 230 V supply, IP54 enclosure, frame FR09 configuration. It is rated 261 A continuous output current and meets EMC category C4.

Key specifications

Order code136U1861
Type codeNXP02612-A5T0SSG-A1A200D200+QGLM+APFIFF09+DPAP+DLES
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power75 kW / 100 HP
Power, high overload55 kW
Rated current261 A
Current, high overload205 A
Mains voltage230 Vac
PhasesThree phase
EnclosureIP54/NEMA12
Frame sizeFR09
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)1150 x 480 x 362 mm
Net weight146 kg
EAN5710108998462

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage2-230 Vac
Current0261261 Amp
Control KeypadAAlpha-numeric display
Enclosure5IP54/NEMA12
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLMMetric conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLESSpanish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+APFIFF09Marine application NXP,NXS
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR09Frame 09
Power rating75K75 kW/100 HP
Motor Power Low Overload [kW]7575
Motor Power High Overload [kW]5555
Dimensions WxHxD [mm]480X1150X362480X1150X362
Continuous Current (NO) [A]261261
Continuous Current (HO) [A]205205

Typical applications

At 75 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 55 kW / 205 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot D: SysBus(1fiber), CAN-MonBus.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 136U1861 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 136H7344

VACON 

VACON NXP Air Cooled AC Drive 75 kW 230V IP54 - 136H7344

The VACON NXP Air Cooled AC Drive with order code 136H7344 and type code NXP02612-A5H0SSG-A1B5000000+DLES is a 75 kW (100 HP), three-phase 230 V supply, IP54 enclosure, frame FR09 configuration. It...
VACON NXP Air Cooled AC Drive 136L3280

VACON 

VACON NXP Air Cooled AC Drive 75 kW 230V IP54 - 136L3280

The VACON NXP Air Cooled AC Drive with order code 136L3280 and type code NXP02612-A5H0SSG-A1A2000000+QGLM+DLES is a 75 kW (100 HP), three-phase 230 V supply, IP54 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC Drive 136L3299

VACON 

VACON NXP Air Cooled AC Drive 75 kW 230V IP54 - 136L3299

The VACON NXP Air Cooled AC Drive with order code 136L3299 and type code NXP02612-A5H0SSG-A1B5000000+QGLM+DLES is a 75 kW (100 HP), three-phase 230 V supply, IP54 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC Drive 132N0184

VACON 

VACON NXP Air Cooled AC Drive 75 kW 230V IP54 - 132N0184

The VACON NXP Air Cooled AC Drive with order code 132N0184 and type code NXP02612-A5T0BSG-A9A2BE00EA is a 75 kW, three-phase 230 V supply, IP54 enclosure, frame FR09 configuration. It is rated 261 A...
VACON NXP Air Cooled AC Drive 137G3427

VACON 

VACON NXP Air Cooled AC Drive 75 kW 230V IP54 - 137G3427

The VACON NXP Air Cooled AC Drive with order code 137G3427 and type code NXP02612-A5T0BSG-A1A2BCBH00+QGLM+FL23+DPAP+DLNL is a 75 kW, three-phase 230 V supply, IP54 enclosure, frame FR09 configuration...