  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 525-690 V
  • VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137X1402
  • VACON NXP Air Cooled AC Drive 137X1402
VACON NXP Air Cooled AC Drive 137X1402

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137X1402

Send inquiry Order code: 137X1402
(You save )
Brand
VACON
SKU:
137X1402
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
560
Rated current (A):
590
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FR11
EMC category:
C4
Brake chopper:
Yes
Control panel:
Alphanumeric Keypad
Type code:
NXP05906-A0T1BSG-A1A2A5D2E9

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137X1402 and type code NXP05906-A0T1BSG-A1A2A5D2E9 is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11 configuration. It is rated 590 A continuous output current, meets EMC category C4 and has an integrated brake chopper.

Key specifications

Order code137X1402
Type codeNXP05906-A0T1BSG-A1A2A5D2E9
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power560 kW
Power, high overload500 kW
Rated current590 A
Current, high overload502 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFR11
EMC categoryC4
Brake chopperIntegrated
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
DimensionsSEE DRAWING
Net weight378 kg
EAN5715253800318

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0590590 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper1Integrated Brake chopper
Electrical ModificationBDC Connection with choke
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR11Frame 11
Motor Power Low Overload [kW]560560
Motor Power High Overload [kW]500500
Dimensions WxHxD [mm]SEE DRAWINGSEE DRAWING
Continuous Current (NO) [A]590590
Continuous Current (HO) [A]502502

Typical applications

At 560 kW, this AC Drive is typically used for high-power marine propulsion, mining and heavy process lines.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
  • For heavy-duty use with high overload the rating is 500 kW / 502 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: 3DI(Enc.10-24V),15/24Vout; slot D: SysBus(1fiber), CAN-MonBus; slot E: 2-port ethernet.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137X1402 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137U0121

VACON 

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137U0121

The VACON NXP Air Cooled AC Drive with order code 137U0121 and type code NXP05906-A0N0TSB-A1A2B400D2+APFIFF06 is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11 configuration. It...
VACON NXP Air Cooled AC Drive 137L8070

VACON 

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137L8070

The VACON NXP Air Cooled AC Drive with order code 137L8070 and type code NXP05906-A0N0TSB-A1A2B4C4D2 is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137L3969

VACON 

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137L3969

The VACON NXP Air Cooled AC Drive with order code 137L3969 and type code NXP05906-A0N0SSG-A9A2000000 is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137U9807

VACON 

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137U9807

The VACON NXP Air Cooled AC Drive with order code 137U9807 and type code NXP05906-A0T0SSG-A1B5D7B5D6+FL23+APFIFF44+GSNT+GADN+LPC2+SPXE is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Air Cooled AC Drive 137L9198

VACON 

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137L9198

The VACON NXP Air Cooled AC Drive with order code 137L9198 and type code NXP05906-G0T0BSB-A1A2000000+FL26+DLCN is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11 configuration. It...