  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 525-690 V
  • VACON NXP Air Cooled AC Drive 400 kW 525-690V IP54 - 137U0714
  • VACON NXP Air Cooled AC Drive 137U0714
VACON NXP Air Cooled AC Drive 137U0714

VACON NXP Air Cooled AC Drive 400 kW 525-690V IP54 - 137U0714

Send inquiry Order code: 137U0714
(You save )
Brand
VACON
SKU:
137U0714
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
400
Rated current (A):
416
Mains voltage:
525-690 V
Enclosure:
IP54
Frame size:
FR10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP04166-A5T0SSB-A8A3B400E2+GABV

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137U0714 and type code NXP04166-A5T0SSB-A8A3B400E2+GABV is a 400 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR10 configuration. It is rated 416 A continuous output current and meets EMC category C4.

Key specifications

Order code137U0714
Type codeNXP04166-A5T0SSB-A8A3B400E2+GABV
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power400 kW
Power, high overload315 kW
Rated current416 A
Current, high overload325 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP54/NEMA12
Frame sizeFR10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)2018 x 595 x 602 mm
Net weight340 kg
EAN5715253689432

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current0416416 Amp
Control KeypadAAlpha-numeric display
Enclosure5IP54/NEMA12
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsB-Fiber+IntegrControl+varn.PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot CB4AI,2AO(mA,isol),+24V/EXT
Option Slot D00No board
Option Slot EE2RS485 (Modbus/N2)
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GABVBureau Veritas
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR10Frame 10
Motor Power Low Overload [kW]400400
Motor Power High Overload [kW]315315
Dimensions WxHxD [mm]595X2018X602595X2018X602
Continuous Current (NO) [A]416416
Continuous Current (HO) [A]325325

Typical applications

At 400 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 315 kW / 325 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: 1RO(NO/NC),1RO(NC), therm; slot C: 2AO(mA,isol),+24V/EXT; slot E: RS485 (Modbus/N2).

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137U0714 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137H9959

VACON 

VACON NXP Air Cooled AC Drive 400 kW 525-690V IP54 - 137H9959

The VACON NXP Air Cooled AC Drive with order code 137H9959 and type code NXP04166-A5L0SSB-A1A2000000 is a 400 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137H6023

VACON 

VACON NXP Air Cooled AC Drive 400 kW 525-690V IP54 - 137H6023

The VACON NXP Air Cooled AC Drive with order code 137H6023 and type code NXP04166-A5T0SSB-A1A30000E9 is a 400 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137U9146

VACON 

VACON NXP Air Cooled AC Drive 3 kW 525-690V IP54 - 137U9146

The VACON NXP Air Cooled AC Drive with order code 137U9146 and type code NXP00046-A5L0SSV-A1AFA500E3+QGLM+FL21+DPAP+DLSE is a 3 kW (4 HP), three-phase 525-690 V supply, IP54 enclosure, frame FR06...
VACON NXP Air Cooled AC Drive 137U3442

VACON 

VACON NXP Air Cooled AC Drive 200 kW 525-690V IP54 - 137U3442

The VACON NXP Air Cooled AC Drive with order code 137U3442 and type code NXP02086-A5T0SSG-A1A2D7D2E9+EMAR is a 200 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR09 configuration. It is...
VACON NXP Air Cooled AC Drive 137U6645

VACON 

VACON NXP Air Cooled AC Drive 30 kW 525-690V IP54 - 137U6645

The VACON NXP Air Cooled AC Drive with order code 137U6645 and type code NXP00346-A5T1SSV-A8B2A500CP+EMAR is a 30 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06 configuration. It is...