  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 208-240 V
  • VACON NXP Air Cooled AC Drive 37 kW 230V IP54 - 137G7985
  • VACON NXP Air Cooled AC Drive 137G7985
VACON NXP Air Cooled AC Drive 137G7985

VACON NXP Air Cooled AC Drive 37 kW 230V IP54 - 137G7985

Send inquiry Order code: 137G7985
(You save )
Brand
VACON
SKU:
137G7985
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
37
Rated current (A):
140
Mains voltage:
230 V
Enclosure:
IP54
Frame size:
FR08
EMC category:
C2
Brake chopper:
Yes
Control panel:
Alphanumeric Keypad
Type code:
NXP01402-A5H1SSV-A1AFB1B4E9+DPAP

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137G7985 and type code NXP01402-A5H1SSV-A1AFB1B4E9+DPAP is a 37 kW, three-phase 230 V supply, IP54 enclosure, frame FR08 configuration. It is rated 140 A continuous output current, meets EMC category C2 and has an integrated brake chopper.

Key specifications

Order code137G7985
Type codeNXP01402-A5H1SSV-A1AFB1B4E9+DPAP
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power37 kW
Power, high overload30 kW
Rated current140 A
Current, high overload105 A
Mains voltage230 Vac
PhasesThree phase
EnclosureIP54/NEMA12
Frame sizeFR08
EMC categoryC2
RFI filterClass A1
Brake chopperIntegrated
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)758 x 288 x 344 mm
Net weight58 kg
EAN5715253342603

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage2-230 Vac
Current0140140 Amp
Control KeypadAAlpha-numeric display
Enclosure5IP54/NEMA12
EMC emission levelsHIEC61800-3
Brake Chopper1Integrated Brake chopper
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot CB16 programmableDI/DO
Option Slot DB4AI,2AO(mA,isol),+24V/EXT
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR08Frame 08
Motor Power Low Overload [kW]3737
Motor Power High Overload [kW]3030
Dimensions WxHxD [mm]288X758X344288X758X344
Continuous Current (NO) [A]140140
Continuous Current (HO) [A]105105
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 37 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C2 suits commercial and industrial networks when installed by a professional.
  • The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
  • For heavy-duty use with high overload the rating is 30 kW / 105 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot C: 6 programmableDI/DO; slot D: 2AO(mA,isol),+24V/EXT; slot E: 2-port ethernet.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137G7985 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 132H9714

VACON 

VACON NXP Air Cooled AC Drive 37 kW 230V IP54 - 132H9714

The VACON NXP Air Cooled AC Drive with order code 132H9714 and type code NXP01402-A5H0SSV-A1A2000000+QGLM+FL23 is a 37 kW, three-phase 230 V supply, IP54 enclosure, frame FR08 configuration. It is...
VACON NXP Air Cooled AC Drive 136H7322

VACON 

VACON NXP Air Cooled AC Drive 37 kW 230V IP54 - 136H7322

The VACON NXP Air Cooled AC Drive with order code 136H7322 and type code NXP01402-A5H0SSV-A1A2000000+DLES is a 37 kW (50 HP), three-phase 230 V supply, IP54 enclosure, frame FR08 configuration. It is...
VACON NXP Air Cooled AC Drive 136X2374

VACON 

VACON NXP Air Cooled AC Drive 37 kW 230V IP54 - 136X2374

The VACON NXP Air Cooled AC Drive with order code 136X2374 and type code NXP01402-A5H1SSV-A1A2A50000+QGLM+LS60 is a 37 kW (50 HP), three-phase 230 V supply, IP54 enclosure, frame FR08 configuration...
VACON NXP Air Cooled AC Drive 136L3296

VACON 

VACON NXP Air Cooled AC Drive 37 kW 230V IP54 - 136L3296

The VACON NXP Air Cooled AC Drive with order code 136L3296 and type code NXP01402-A5H0SSV-A1B5000000+QGLM+DLES is a 37 kW (50 HP), three-phase 230 V supply, IP54 enclosure, frame FR08 configuration...
VACON NXP Air Cooled AC Drive 132N5237

VACON 

VACON NXP Air Cooled AC Drive 37 kW 230V IP54 - 132N5237

The VACON NXP Air Cooled AC Drive with order code 132N5237 and type code NXP01402-A5T0SSV-A1A2000000+APFIFF09+DPAP+DLES is a 37 kW, three-phase 230 V supply, IP54 enclosure, frame FR08 configuration...