VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP54 - 137N0375

Send inquiry Order code: 137N0375
(You save )
Brand
VACON
SKU:
137N0375
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
37.5
Rated current (A):
41
Mains voltage:
525-690 V
Enclosure:
IP54
Frame size:
FR07
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP00416-A5T0SSV-A1A30000CI

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137N0375 and type code NXP00416-A5T0SSV-A1A30000CI is a 37.5 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR07 configuration. It is rated 41 A continuous output current and meets EMC category C4.

Key specifications

Order code137N0375
Type codeNXP00416-A5T0SSV-A1A30000CI
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power37.5 kW
Power, high overload30 kW
Rated current41 A
Current, high overload34 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP54/NEMA12
Frame sizeFR07
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)591 x 237 x 257 mm
Net weight35 kg
EAN5715253580920

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current004141 Amp
Control KeypadAAlpha-numeric display
Enclosure5IP54/NEMA12
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot C00No board
Option Slot D00No board
Option Slot ECIModbus/TCP
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR07Frame 07
Motor Power Low Overload [kW]37,537,5
Motor Power High Overload [kW]3030
Dimensions WxHxD [mm]237X591X257237X591X257
Continuous Current (NO) [A]4141
Continuous Current (HO) [A]3434

Typical applications

At 37.5 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 30 kW / 34 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 1RO(NO/NC),1RO(NC), therm; slot E: Modbus/TCP.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137N0375 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137L5219

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP54 - 137L5219

The VACON NXP Air Cooled AC Drive with order code 137L5219 and type code NXP00416-A5L0SSV-A1A20000E5+FL25+DPAP+DLES is a 37.5 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR07...
VACON NXP Air Cooled AC Drive 137N8136

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP54 - 137N8136

The VACON NXP Air Cooled AC Drive with order code 137N8136 and type code NXP00416-A5T0SSV-A1AF0000E9 is a 37.5 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137L8055

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP54 - 137L8055

The VACON NXP Air Cooled AC Drive with order code 137L8055 and type code NXP00416-A5L0SSV-A1A30000CI is a 37.5 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N1240

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP54 - 137N1240

The VACON NXP Air Cooled AC Drive with order code 137N1240 and type code NXP00416-A5T0SSV-A8A2000000+QGLM+FL23 is a 37.5 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR07 configuration. It...
VACON NXP Air Cooled AC Drive 137N3620

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP54 - 137N3620

The VACON NXP Air Cooled AC Drive with order code 137N3620 and type code NXP00416-A5T0SSV-A1A200E600+QGLM is a 37.5 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR07 configuration. It is...