  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 380-500 V
  • VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 137U0741
  • VACON NXP Air Cooled AC Drive 137U0741
VACON NXP Air Cooled AC Drive 137U0741

VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 137U0741

Send inquiry Order code: 137U0741
(You save )
Brand
VACON
SKU:
137U0741
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
3
Rated current (A):
7
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR04
EMC category:
C4
Brake chopper:
Yes
Control panel:
Alphanumeric Keypad
Type code:
NXP00075-A2T2SSV-A1AFA50000

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137U0741 and type code NXP00075-A2T2SSV-A1AFA50000 is a 3 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 7 A continuous output current, meets EMC category C4 and has an integrated brake chopper.

Key specifications

Order code137U0741
Type codeNXP00075-A2T2SSV-A1AFA50000
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power3 kW
Power, high overload2.2 kW
Rated current7 A
Current, high overload5.6 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR04
EMC categoryC4
Brake chopperIntegrated
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)327 x 128 x 190 mm
Net weight5 kg
EAN5715253689708

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current00077 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper2Int. Brake chopper /w resistor
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR04Frame 04
Motor Power Low Overload [kW]33
Motor Power High Overload [kW]2,22,2
Dimensions WxHxD [mm]128X327X190128X327X190
Continuous Current (NO) [A]7,67,6
Continuous Current (HO) [A]5,65,6
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 3 kW, this AC Drive is typically used for precise machine control, hoists and positioning applications.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
  • For heavy-duty use with high overload the rating is 2.2 kW / 5.6 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot C: 3DI(Enc.10-24V),15/24Vout.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137U0741 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 132N2697

VACON 

VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 132N2697

The VACON NXP Air Cooled AC Drive with order code 132N2697 and type code NXP00075-F2H1SSS-A1AF000000+APFIFF33+LS60+DNOT+DLBR is a 3 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Air Cooled AC Drive 132X2585

VACON 

VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 132X2585

The VACON NXP Air Cooled AC Drive with order code 132X2585 and type code NXP00075-A2H1SSV-A1A20000C2 is a 3 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 7 A...
VACON NXP Air Cooled AC Drive 137U0439

VACON 

VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 137U0439

The VACON NXP Air Cooled AC Drive with order code 137U0439 and type code NXP00075-A2H1SSV-A1A2000000+APFIFF20 is a 3 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is...
VACON NXP Air Cooled AC Drive 137G2373

VACON 

VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 137G2373

The VACON NXP Air Cooled AC Drive with order code 137G2373 and type code NXP00075-A2H1SSV-A1A300E900+QGLM+FL28+APFIFF20 is a 3 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Air Cooled AC Drive 137G2738

VACON 

VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 137G2738

The VACON NXP Air Cooled AC Drive with order code 137G2738 and type code NXP00075-A2H1SSV-A1A2000000+APFIFF08 is a 3 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is...