VACON NXP Air Cooled AC Drive 137U9915

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP00 - 137U9915

Send inquiry Order code: 137U9915
(You save )
Brand
VACON
SKU:
137U9915
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
250
Power (HP):
350
Rated current (A):
460
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FR10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP04605-A0T0SSB-A1AFA5B4EA+APFIFF09+DNOT+GABV

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137U9915 and type code NXP04605-A0T0SSB-A1AFA5B4EA+APFIFF09+DNOT+GABV is a 250 kW (350 HP), three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated 460 A continuous output current and meets EMC category C4.

Key specifications

Order code137U9915
Type codeNXP04605-A0T0SSB-A1AFA5B4EA+APFIFF09+DNOT+GABV
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power250 kW / 350 HP
Power, high overload200 kW
Rated current460 A
Current, high overload385 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFR10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
DimensionsSEE DRAWING
Net weight238 kg
EAN5715253785233

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0460460 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsB-Fiber+IntegrControl+varn.PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot DB4AI,2AO(mA,isol),+24V/EXT
Option Slot EEAAdvanced 2-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DNOTNo manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+APFIFF09Marine application NXP,NXS
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+GABVBureau Veritas
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR10Frame 10
Power rating250250 kW/350 HP
Motor Power Low Overload [kW]250250
Motor Power High Overload [kW]200200
Dimensions WxHxD [mm]SEE DRAWINGSEE DRAWING
Continuous Current (NO) [A]460460
Continuous Current (HO) [A]385385
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD
customized ID+BM26+BM26

Typical applications

At 250 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 200 kW / 385 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot C: 3DI(Enc.10-24V),15/24Vout; slot D: 2AO(mA,isol),+24V/EXT; slot E: Advanced 2-port ethernet.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137U9915 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137U5546

VACON 

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP00 - 137U5546

The VACON NXP Air Cooled AC Drive with order code 137U5546 and type code NXP05205-A0N0SSB-A1A200D2E9 is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N5967

VACON 

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP00 - 137N5967

The VACON NXP Air Cooled AC Drive with order code 137N5967 and type code NXP04605-G0N0NSB-A1A2B2B400 is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N7577

VACON 

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP00 - 137N7577

The VACON NXP Air Cooled AC Drive with order code 137N7577 and type code NXP04605-A0T1SSO-A1A2000000+FL25+LS60+DLES is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration...
VACON NXP Air Cooled AC Drive 137N8541

VACON 

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP00 - 137N8541

The VACON NXP Air Cooled AC Drive with order code 137N8541 and type code NXP05205-A0N1SSG-A1A3B400E2+LS60+DLCN is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC Drive 137N8141

VACON 

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP00 - 137N8141

The VACON NXP Air Cooled AC Drive with order code 137N8141 and type code NXP05205-A0N1SSG-A1A3B400E2+FL26+LS60+DLCN is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration...