VACON NXP Air Cooled AC Drive 137N2347

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP54 - 137N2347

Send inquiry Order code: 137N2347
(You save )
Brand
VACON
SKU:
137N2347
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
200
Rated current (A):
385
Mains voltage:
380-500 V
Enclosure:
IP54
Frame size:
FR10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP03855-A5T0SSB-A1A3000000+FL21+APFIFF09

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137N2347 and type code NXP03855-A5T0SSB-A1A3000000+FL21+APFIFF09 is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It is rated 385 A continuous output current and meets EMC category C4.

Key specifications

Order code137N2347
Type codeNXP03855-A5T0SSB-A1A3000000+FL21+APFIFF09
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power200 kW
Power, high overload160 kW
Rated current385 A
Current, high overload300 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP54/NEMA12
Frame sizeFR10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)2018 x 595 x 602 mm
Net weight340 kg
EAN5715253601090

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0385385 Amp
Control KeypadAAlpha-numeric display
Enclosure5IP54/NEMA12
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsB-Fiber+IntegrControl+varn.PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA31RO(NO/NC),1RO(NC), therm
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL21UK,FI,SE,DK,DE;Nordic
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+APFIFF09Marine application NXP,NXS
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR10Frame 10
Motor Power Low Overload [kW]200200
Motor Power High Overload [kW]160160
Dimensions WxHxD [mm]595X2018X602595X2018X602
Continuous Current (NO) [A]385385
Continuous Current (HO) [A]300300

Typical applications

At 200 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 160 kW / 300 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 1RO(NO/NC),1RO(NC), therm.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137N2347 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137U1489

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP54 - 137U1489

The VACON NXP Air Cooled AC Drive with order code 137U1489 and type code NXP03855-A5L0SSB-A1A2000000+DPAP is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It is...
VACON NXP Air Cooled AC Drive 137G9282

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP54 - 137G9282

The VACON NXP Air Cooled AC Drive with order code 137G9282 and type code NXP03855-A5T0OSB-A1A2B2B500+APFIFF09+GABV is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration...
VACON NXP Air Cooled AC Drive 137L4540

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP54 - 137L4540

The VACON NXP Air Cooled AC Drive with order code 137L4540 and type code NXP03855-A5T0OSB-A1A2B40000+DPAP is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It is...
VACON NXP Air Cooled AC Drive 137N0408

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP54 - 137N0408

The VACON NXP Air Cooled AC Drive with order code 137N0408 and type code NXP03855-A5L0OSB-A1A2B4E500+GSSE is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It is...
VACON NXP Air Cooled AC Drive 137X1499

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP54 - 137X1499

The VACON NXP Air Cooled AC Drive with order code 137X1499 and type code NXP03855-A5L0SSB-A1AFB200E2 is a 200 kW (300 HP), three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It...