  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 380-500 V
  • VACON NXP Air Cooled AC Drive 200 kW 380-500V IP21 - 136U1148
  • VACON NXP Air Cooled AC Drive 136U1148
VACON NXP Air Cooled AC Drive 136U1148

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP21 - 136U1148

Send inquiry Order code: 136U1148
(You save )
Brand
VACON
SKU:
136U1148
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
200
Power (HP):
300
Rated current (A):
385
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR10
EMC category:
C3
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP03855-A2L0SSB-A1AFA5D2CP

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 136U1148 and type code NXP03855-A2L0SSB-A1AFA5D2CP is a 200 kW (300 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR10 configuration. It is rated 385 A continuous output current and meets EMC category C3.

Key specifications

Order code136U1148
Type codeNXP03855-A2L0SSB-A1AFA5D2CP
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power200 kW / 300 HP
Power, high overload160 kW
Rated current385 A
Current, high overload300 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR10
EMC categoryC3
RFI filterClass A2
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)2018 x 595 x 602 mm
Net weight340 kg
EAN5710108991364

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0385385 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsLIEC61800-3, 2. environment
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsB-Fiber+IntegrControl+varn.PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot ECPPROFINET
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR10Frame 10
Power rating200200 kW/300 HP
Motor Power Low Overload [kW]200200
Motor Power High Overload [kW]160160
Dimensions WxHxD [mm]595X2018X602595X2018X602
Continuous Current (NO) [A]385385
Continuous Current (HO) [A]300300
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 200 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C3 is intended for industrial (second environment) networks.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 160 kW / 300 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot C: 3DI(Enc.10-24V),15/24Vout; slot D: SysBus(1fiber), CAN-MonBus; slot E: PROFINET.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 136U1148 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137N7849

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP21 - 137N7849

The VACON NXP Air Cooled AC Drive with order code 137N7849 and type code NXP03855-A2L1SSB-A1A2000000+LS60+DLES is a 200 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC Drive 137L6064

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP21 - 137L6064

The VACON NXP Air Cooled AC Drive with order code 137L6064 and type code NXP03855-A2L0SSB-A1AF00E900+DPAP is a 200 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR10 configuration. It is...
VACON NXP Air Cooled AC Drive 137L7973

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP21 - 137L7973

The VACON NXP Air Cooled AC Drive with order code 137L7973 and type code NXP03855-A2T0BSB-A1A20000E2+DPAP+DLFR is a 200 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC Drive 137G9655

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP21 - 137G9655

The VACON NXP Air Cooled AC Drive with order code 137G9655 and type code NXP03855-A2T1SSB-A1A20000CQ+FL25+LS60+DPAP+DLES is a 200 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR10...
VACON NXP Air Cooled AC Drive 137G0290

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP21 - 137G0290

The VACON NXP Air Cooled AC Drive with order code 137G0290 and type code NXP03855-A2L0OSB-A1AFA5D2CP+DLFR is a 200 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR10 configuration. It is...