VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137H7422

Send inquiry Order code: 137H7422
(You save )
Brand
VACON
SKU:
137H7422
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
200
Rated current (A):
385
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FR10
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP03855-A0N0SSB-A1A2B4D200

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137H7422 and type code NXP03855-A0N0SSB-A1A2B4D200 is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated 385 A continuous output current and meets EMC category C4.

Key specifications

Order code137H7422
Type codeNXP03855-A0N0SSB-A1A2B4D200
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power200 kW
Power, high overload160 kW
Rated current385 A
Current, high overload300 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFR10
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
DimensionsSEE DRAWING
Net weight207 kg
EAN5715253443157

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0385385 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsNno EMC protection
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsB-Fiber+IntegrControl+varn.PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot CB4AI,2AO(mA,isol),+24V/EXT
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR10Frame 10
Motor Power Low Overload [kW]200200
Motor Power High Overload [kW]160160
Dimensions WxHxD [mm]SEE DRAWINGSEE DRAWING
Continuous Current (NO) [A]385385
Continuous Current (HO) [A]300300

Typical applications

At 200 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 160 kW / 300 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot C: 2AO(mA,isol),+24V/EXT; slot D: SysBus(1fiber), CAN-MonBus.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137H7422 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137U1540

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137U1540

The VACON NXP Air Cooled AC Drive with order code 137U1540 and type code NXP03855-G0N0NSB-A1A2A5E6B4+FL26+DLCN is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC Drive 137U5223

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137U5223

The VACON NXP Air Cooled AC Drive with order code 137U5223 and type code NXP03855-A0T0SSB-A1A2D7B500+APFIFF44+GAAB is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration...
VACON NXP Air Cooled AC Drive 137N8275

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137N8275

The VACON NXP Air Cooled AC Drive with order code 137N8275 and type code NXP03855-A0T0SSG-A1A2B400E9+APFIFF09+DLFR+GALR is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10...
VACON NXP Air Cooled AC Drive 137N6843

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137N6843

The VACON NXP Air Cooled AC Drive with order code 137N6843 and type code NXP03855-G0N0BSB-A1A30000E2+FL26+DLCN is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC Drive 137U1162

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137U1162

The VACON NXP Air Cooled AC Drive with order code 137U1162 and type code NXP03855-A0T0SSG-A1A3D70000 is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated...