VACON NXP Air Cooled AC Drive 137U1308

VACON NXP Air Cooled AC Drive 15 kW 380-500V IP21 - 137U1308

Send inquiry Order code: 137U1308
(You save )
Brand
VACON
SKU:
137U1308
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
15
Rated current (A):
31
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR05
EMC category:
C4
Brake chopper:
Yes
Control panel:
Graphical Keypad
Type code:
NXP00315-G2T2SSV-A1A200E3E3

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137U1308 and type code NXP00315-G2T2SSV-A1A200E3E3 is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 31 A continuous output current, meets EMC category C4 and has an integrated brake chopper.

Key specifications

Order code137U1308
Type codeNXP00315-G2T2SSV-A1A200E3E3
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power15 kW
Power, high overload11 kW
Rated current31 A
Current, high overload23 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR05
EMC categoryC4
Brake chopperIntegrated
Control panelGraphical Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)417 x 144 x 214 mm
Net weight8.1 kg
EAN5715253696126

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current003131 Amp
Control KeypadGGraphical panel
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper2Int. Brake chopper /w resistor
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot DE3PROFIBUS DP
Option Slot EE3PROFIBUS DP
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR05Frame 05
Motor Power Low Overload [kW]1515
Motor Power High Overload [kW]1111
Dimensions WxHxD [mm]144X417X214144X417X214
Continuous Current (NO) [A]3131
Continuous Current (HO) [A]2323

Typical applications

At 15 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
  • For heavy-duty use with high overload the rating is 11 kW / 23 A.
  • It is supplied with a graphical keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot D: PROFIBUS DP; slot E: PROFIBUS DP.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137U1308 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137U8099

VACON 

VACON NXP Air Cooled AC Drive 15 kW 380-500V IP21 - 137U8099

The VACON NXP Air Cooled AC Drive with order code 137U8099 and type code NXP00315-A2T2SSV-A9A200E700 is a 15 kW (20 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is...
VACON NXP Air Cooled AC Drive 137U4395

VACON 

VACON NXP Air Cooled AC Drive 15 kW 380-500V IP21 - 137U4395

The VACON NXP Air Cooled AC Drive with order code 137U4395 and type code NXP00315-A2H1SSV-00AF0000E3 is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 31...
VACON NXP Air Cooled AC Drive 137N6253

VACON 

VACON NXP Air Cooled AC Drive 15 kW 380-500V IP21 - 137N6253

The VACON NXP Air Cooled AC Drive with order code 137N6253 and type code NXP00315-A2H1SSV-A1A2000000+FL24+APCZFF33+DNOT is a 15 kW (20 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR05...
VACON NXP Air Cooled AC Drive 137G8936

VACON 

VACON NXP Air Cooled AC Drive 15 kW 380-500V IP21 - 137G8936

The VACON NXP Air Cooled AC Drive with order code 137G8936 and type code NXP00315-F2H1SSV-A1A2000000+FL25+LS60+DLBR is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration...
VACON NXP Air Cooled AC Drive 137H1678

VACON 

VACON NXP Air Cooled AC Drive 15 kW 380-500V IP21 - 137H1678

The VACON NXP Air Cooled AC Drive with order code 137H1678 and type code NXP00315-A2T2SSV-A1A2000000 is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 31...