  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 380-500 V
  • VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137G6002
  • VACON NXP Air Cooled AC Drive 137G6002
VACON NXP Air Cooled AC Drive 137G6002

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137G6002

Send inquiry Order code: 137G6002
(You save )
Brand
VACON
SKU:
137G6002
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
132
Rated current (A):
261
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR09
EMC category:
C2
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP02615-A2H0SSG-A8AFBMD2EA+APFIFF40

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137G6002 and type code NXP02615-A2H0SSG-A8AFBMD2EA+APFIFF40 is a 132 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration. It is rated 261 A continuous output current and meets EMC category C2.

Key specifications

Order code137G6002
Type codeNXP02615-A2H0SSG-A8AFBMD2EA+APFIFF40
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power132 kW
Power, high overload110 kW
Rated current261 A
Current, high overload205 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR09
EMC categoryC2
RFI filterClass A1
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 w.galv.isol 2AI&1AO
Dimensions (H x W x D)1150 x 480 x 362 mm
Net weight146 kg
EAN5715253321363

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current0261261 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsHIEC61800-3
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA8OPTA1 w.galv.isol 2AI&1AO
Option Slot BAFSTO, ATEX therm
Option Slot CBMAdvanced safety + HTL/TTL
Option Slot DD2SysBus(1fiber), CAN-MonBus
Option Slot EEAAdvanced 2-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+APFIFF40SIA II application NXP,NXI
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR09Frame 09
Motor Power Low Overload [kW]132132
Motor Power High Overload [kW]110110
Dimensions WxHxD [mm]480X1150X362480X1150X362
Continuous Current (NO) [A]261261
Continuous Current (HO) [A]205205
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 132 kW, this AC Drive is typically used for cranes, winders, paper machines, rolling mills, marine and offshore applications.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C2 suits commercial and industrial networks when installed by a professional.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 110 kW / 205 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 w.galv.isol 2AI&1AO; slot B: STO, ATEX therm; slot C: Advanced safety + HTL/TTL; slot D: SysBus(1fiber), CAN-MonBus; slot E: Advanced 2-port ethernet.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137G6002 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137U8617

VACON 

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137U8617

The VACON NXP Air Cooled AC Drive with order code 137U8617 and type code NXP02615-A2H0SSG-A1A2BHCP00+QGLM+FL21+DPAP+DLSE is a 132 kW (200 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR09...
VACON NXP Air Cooled AC Drive 137X0491

VACON 

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137X0491

The VACON NXP Air Cooled AC Drive with order code 137X0491 and type code NXP02615-A2T1SSG-A1AFA5B1E6 is a 132 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N7713

VACON 

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137N7713

The VACON NXP Air Cooled AC Drive with order code 137N7713 and type code NXP02615-G2H0SSG-A1A200E200+FL26+DPAP+DLCN is a 132 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC Drive 137N6012

VACON 

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137N6012

The VACON NXP Air Cooled AC Drive with order code 137N6012 and type code NXP02615-A2H0SSG-A1A200E200+FL21+DPAP+DLCN is a 132 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC Drive 137U0358

VACON 

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137U0358

The VACON NXP Air Cooled AC Drive with order code 137U0358 and type code NXP02615-A2H0SSG-A1AF000000+FL26+DPAP+DLCN is a 132 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration...