VACON NXP Air Cooled AC Drive 137N9512

VACON NXP Air Cooled AC Drive 11 kW 525-690V IP54 - 137N9512

Send inquiry Order code: 137N9512
(You save )
Brand
VACON
SKU:
137N9512
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
11
Rated current (A):
13
Mains voltage:
525-690 V
Enclosure:
IP54
Frame size:
FR06
EMC category:
C4
Brake chopper:
Yes
Control panel:
Alphanumeric Keypad
Type code:
NXP00136-A5T1SSV-00AFA5E9E9+EMAR

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137N9512 and type code NXP00136-A5T1SSV-00AFA5E9E9+EMAR is a 11 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06 configuration. It is rated 13 A continuous output current, meets EMC category C4 and has an integrated brake chopper.

Key specifications

Order code137N9512
Type codeNXP00136-A5T1SSV-00AFA5E9E9+EMAR
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power11 kW
Power, high overload7.5 kW
Rated current13 A
Current, high overload10 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP54/NEMA12
Frame sizeFR06
EMC categoryC4
Brake chopperIntegrated
Control panelAlphanumeric Keypad
Standard I/ONo board
Dimensions (H x W x D)557 x 195 x 237 mm
Net weight18.5 kg
EAN5715253676753

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current001313 Amp
Control KeypadAAlpha-numeric display
Enclosure5IP54/NEMA12
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper1Integrated Brake chopper
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot A00No board
Option Slot BAFSTO, ATEX therm
Option Slot CA53DI(Enc.10-24V),15/24Vout
Option Slot DE92-port ethernet
Option Slot EE92-port ethernet
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DQCKQuick guide user manual
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+EMARMarine Approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR06Frame 06
Motor Power Low Overload [kW]1111
Motor Power High Overload [kW]7,57,5
Dimensions WxHxD [mm]195X557X237195X557X237
Continuous Current (NO) [A]13,513,5
Continuous Current (HO) [A]1010
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 11 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
  • For heavy-duty use with high overload the rating is 7.5 kW / 10 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot B: STO, ATEX therm; slot C: 3DI(Enc.10-24V),15/24Vout; slot D: 2-port ethernet; slot E: 2-port ethernet.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137N9512 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137N9886

VACON 

VACON NXP Air Cooled AC Drive 11 kW 525-690V IP54 - 137N9886

The VACON NXP Air Cooled AC Drive with order code 137N9886 and type code NXP00136-A5L0SSV-A1A20000EA is a 11 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06 configuration. It is rated 13...
VACON NXP Air Cooled AC Drive 137U4731

VACON 

VACON NXP Air Cooled AC Drive 11 kW 525-690V IP54 - 137U4731

The VACON NXP Air Cooled AC Drive with order code 137U4731 and type code NXP00136-A5T1SSV-A1A2000000+FL23+DPAP+DLNL is a 11 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06 configuration...
VACON NXP Air Cooled AC Drive 137U6188

VACON 

VACON NXP Air Cooled AC Drive 11 kW 525-690V IP54 - 137U6188

The VACON NXP Air Cooled AC Drive with order code 137U6188 and type code NXP00136-A5L1SSV-A1A3000000+QGLM+FL23+LS60+DPAP is a 11 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06...
VACON NXP Air Cooled AC Drive 132L4738

VACON 

VACON NXP Air Cooled AC Drive 11 kW 525-690V IP54 - 132L4738

The VACON NXP Air Cooled AC Drive with order code 132L4738 and type code NXP00136-A5T1SSV-A1A3000000+QGLM is a 11 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06 configuration. It is...
VACON NXP Air Cooled AC Drive 137G9414

VACON 

VACON NXP Air Cooled AC Drive 11 kW 525-690V IP54 - 137G9414

The VACON NXP Air Cooled AC Drive with order code 137G9414 and type code NXP00136-A5L1SSV-A1A3000000+QGLM+FL23+DPAP+DLDE is a 11 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06...