  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 380-500 V
  • VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 137H4592
  • VACON NXP Air Cooled AC Drive 137H4592
VACON NXP Air Cooled AC Drive 137H4592

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 137H4592

Send inquiry Order code: 137H4592
(You save )
Brand
VACON
SKU:
137H4592
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
11
Rated current (A):
22
Mains voltage:
380-500 V
Enclosure:
IP21
Frame size:
FR05
EMC category:
C4
Brake chopper:
Yes
Control panel:
Alphanumeric Keypad
Type code:
NXP00225-A2T1SSV-A1AFBB00E9+FL24+APFIFF09+DPAP+EMAR

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137H4592 and type code NXP00225-A2T1SSV-A1AFBB00E9+FL24+APFIFF09+DPAP+EMAR is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 22 A continuous output current, meets EMC category C4 and has an integrated brake chopper.

Key specifications

Order code137H4592
Type codeNXP00225-A2T1SSV-A1AFBB00E9+FL24+APFIFF09+DPAP+EMAR
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power11 kW
Power, high overload7.5 kW
Rated current22 A
Current, high overload16 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP21/NEMA1
Frame sizeFR05
EMC categoryC4
Brake chopperIntegrated
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
Dimensions (H x W x D)417 x 144 x 214 mm
Net weight8.1 kg
EAN5715253413730

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current002222 Amp
Control KeypadAAlpha-numeric display
Enclosure2IP21/NEMA1
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper1Integrated Brake chopper
Electrical ModificationS6-pulse with choke
Card ModificationsV-DirectConn. w Varnished Boards
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGLCInch conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BAFSTO, ATEX therm
Option Slot CBBENDAT enc 2DO (RS422)
Option Slot D00No board
Option Slot EE92-port ethernet
Firmware language package+FL24UK,EE,PL,CZ,DE;CentEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+APFIFF09Marine application NXP,NXS
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approval+EMARMarine Approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR05Frame 05
Motor Power Low Overload [kW]1111
Motor Power High Overload [kW]7,57,5
Dimensions WxHxD [mm]144X417X214144X417X214
Continuous Current (NO) [A]2323
Continuous Current (HO) [A]1616
ATEX Marking 1ATEX: II (2) GDATEX: II (2) GD

Typical applications

At 11 kW, this AC Drive is typically used for cranes, hoists, winches, extruders, test benches and paper and steel process lines.

Configuration notes

  • IP21 / UL Type 1 suits clean indoor electrical rooms.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
  • For heavy-duty use with high overload the rating is 7.5 kW / 16 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: STO, ATEX therm; slot C: ENDAT enc 2DO (RS422); slot E: 2-port ethernet.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137H4592 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 132L9985

VACON 

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 132L9985

The VACON NXP Air Cooled AC Drive with order code 132L9985 and type code NXP00225-A2H1SSV-A1AF00E300+QGLM+FL23+DPAP is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration...
VACON NXP Air Cooled AC Drive 132N0429

VACON 

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 132N0429

The VACON NXP Air Cooled AC Drive with order code 132N0429 and type code NXP00225-A2T2SSV-A1AF00CI00 is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 22...
VACON NXP Air Cooled AC Drive 132N1987

VACON 

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 132N1987

The VACON NXP Air Cooled AC Drive with order code 132N1987 and type code NXP00225-A2H1SSV-A1A30000C7 is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 22...
VACON NXP Air Cooled AC Drive 132H4098

VACON 

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 132H4098

The VACON NXP Air Cooled AC Drive with order code 132H4098 and type code NXP00225-A2H1SSV-A1A3000000+DPAP is a 11 kW (15 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration...
VACON NXP Air Cooled AC Drive 132L5260

VACON 

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 132L5260

The VACON NXP Air Cooled AC Drive with order code 132L5260 and type code NXP00225-G2H2SSV-A1A2A40000+FL26+DPAP+DLRU is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration...