VACON NXP Air Cooled AC Drive 137U7218

VACON NXP Air Cooled AC Drive 1000 kW 380-500V IP00 - 137U7218

Send inquiry Order code: 137U7218
(You save )
Brand
VACON
SKU:
137U7218
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
1000
Rated current (A):
1770
Mains voltage:
380-500 V
Enclosure:
IP00
Frame size:
FR14
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP17705-A0T0SSG-A1A20000CQ

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 137U7218 and type code NXP17705-A0T0SSG-A1A20000CQ is a 1000 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR14 configuration. It is rated 1770 A continuous output current and meets EMC category C4.

Key specifications

Order code137U7218
Type codeNXP17705-A0T0SSG-A1A20000CQ
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power1000 kW
Power, high overload900 kW
Rated current1770 A
Current, high overload1600 A
Mains voltage380 – 500 Vac (465-800 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFR14
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/O6DI,DO,2AI,1AO,+10Vr,+24V
DimensionsSEE DRAWING
Net weight1404 kg
EAN5715253757179

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage5-380 – 500 Vac (465-800 Vdc)
Current17701770 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA16DI,DO,2AI,1AO,+10Vr,+24V
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot ECQEtherNet/IP
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR142xFrame 13
Motor Power Low Overload [kW]10001000
Motor Power High Overload [kW]900900
Dimensions WxHxD [mm]SEE DRAWINGSEE DRAWING
Continuous Current (NO) [A]17701770
Continuous Current (HO) [A]16001600

Typical applications

At 1000 kW, this AC Drive is typically used for high-power marine propulsion, mining and heavy process lines.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 900 kW / 1600 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: 6DI,DO,2AI,1AO,+10Vr,+24V; slot B: 2RO(NO/NC); slot E: EtherNet/IP.

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 137U7218 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 132N8856

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 380-500V IP00 - 132N8856

The VACON NXP Air Cooled AC Drive with order code 132N8856 and type code NXP17705-A0T0SSG-A1A200C300 is a 1000 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR14 configuration. It is rated...
VACON NXP Air Cooled AC Drive 132N8485

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 380-500V IP00 - 132N8485

The VACON NXP Air Cooled AC Drive with order code 132N8485 and type code NXP17705-A0N0SSG-A1AF0000E2+LS60 is a 1000 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR14 configuration. It is...
VACON NXP Air Cooled AC Drive 137U1809

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 380-500V IP00 - 137U1809

The VACON NXP Air Cooled AC Drive with order code 137U1809 and type code NXP17705-A0N0SSG-ANA20000E2 is a 1000 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR14 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N7701

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 380-500V IP00 - 137N7701

The VACON NXP Air Cooled AC Drive with order code 137N7701 and type code NXP17705-A0N0SSG-A1A200E300 is a 1000 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR14 configuration. It is rated...
VACON NXP Air Cooled AC Drive 136L3949

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 380-500V IP00 - 136L3949

The VACON NXP Air Cooled AC Drive with order code 136L3949 and type code NXP17705-A0T0SSG-A9A2000000 is a 1000 kW (1350 HP), three-phase 380-500 V supply, IP00 enclosure, frame FR14 configuration. It...