  • Search
  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Air Cooled 525-690 V
  • VACON NXP Air Cooled AC Drive 1000 kW 525-690V IP00 - 136L3962
  • VACON NXP Air Cooled AC Drive 136L3962
VACON NXP Air Cooled AC Drive 136L3962

VACON NXP Air Cooled AC Drive 1000 kW 525-690V IP00 - 136L3962

Send inquiry Order code: 136L3962
(You save )
Brand
VACON
SKU:
136L3962
UPC:
Condition:
New
Series:
VACON NXP Air Cooled
Power (kW):
1000
Power (HP):
1350
Rated current (A):
1030
Mains voltage:
525-690 V
Enclosure:
IP00
Frame size:
FR13
EMC category:
C4
Brake chopper:
No
Control panel:
Alphanumeric Keypad
Type code:
NXP10306-A0T0SSG-A9A2000000

Adding to cart… The item has been added

Description

The VACON NXP Air Cooled AC Drive with order code 136L3962 and type code NXP10306-A0T0SSG-A9A2000000 is a 1000 kW (1350 HP), three-phase 525-690 V supply, IP00 enclosure, frame FR13 configuration. It is rated 1030 A continuous output current and meets EMC category C4.

Key specifications

Order code136L3962
Type codeNXP10306-A0T0SSG-A9A2000000
SeriesVACON® NXP Air Cooled
Product typeAC Drive
Rated power1000 kW / 1350 HP
Power, high overload900 kW
Rated current1030 A
Current, high overload920 A
Mains voltage525 – 690 Vac (640-1100 Vdc)
PhasesThree phase
EnclosureIP00
Frame sizeFR13
EMC categoryC4
Brake chopperNot included
Control panelAlphanumeric Keypad
Standard I/OOPTA1 with 2,5mm2 conn.
Dimensions2X(239X1030X372) + (708X1032X5
Net weight670 kg
EAN5710108805272

Type code configuration

OptionCodeSelection
Product GroupNXPNXP Frequency Converter
Customized Drive+BM26Vacon Dark Grey NXP
Mechanical ModificationSStandard air cooled drive
Mains voltage6-525 – 690 Vac (640-1100 Vdc)
Current10301030 Amp
Control KeypadAAlpha-numeric display
Enclosure0IP00
EMC emission levelsTIEC61800-3 for IT networks
Brake Chopper0No Brake
Electrical ModificationS6-pulse with choke
Card ModificationsG-FiberConnection+Varnished PCB
Shipping Package+GSCBCardboard box as Shipping pack
Warranty+WT01Warranty 12/18 months
Gland Plate Option+QGNONo conduit plate
Option Slot AA9OPTA1 with 2,5mm2 conn.
Option Slot BA22RO(NO/NC)
Option Slot C00No board
Option Slot D00No board
Option Slot E00No board
Firmware language package+FL22UK,FR,IT,ES,PT;WestEur
Documentation Level+DPAPPaper manuals
Documentation Lang. Preference+DLUKEnglish
System Firmware+FNP02System software NXP
Software licenseNONEno software license
Application+A000No Special Application
Parameter SetNONEnone
Motor Parameter Default+LS50Default Motor frequency 50HZ
Labeling options+LPC1no additional labels
CE Approval+GACECE Approval
UL Approval+GAULUL approval
RCM Approval+GACTRCM Approval N16307
Marine approvalNONEno marine approval
KC Approval+GAKCKorean Approval
Ukrainian Approval+GAUAUkrainian Approval
EAC Approval+GAEAEAC Approval
Frame SizeFR13Frame 13
Power rating1M01.0 MW/1350 HP
Motor Power Low Overload [kW]10001000
Motor Power High Overload [kW]900900
Dimensions WxHxD [mm]2X(239X1030X372) + (708X1032X52X(239X1030X372) + (708X1032X5
Continuous Current (NO) [A]10301030
Continuous Current (HO) [A]920920

Typical applications

At 1000 kW, this AC Drive is typically used for high-power marine propulsion, mining and heavy process lines.

Configuration notes

  • IP00 is an open module for mounting inside a cabinet or switchgear.
  • EMC category C4 has no internal RFI filter and is intended for IT (ungrounded) networks or installations with an external filter.
  • There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
  • For heavy-duty use with high overload the rating is 900 kW / 920 A.
  • It is supplied with an alphanumeric keypad for local control and parameter setting.
  • Installed option boards: slot A: OPTA1 with 2,5mm2 conn.; slot B: 2RO(NO/NC).

About the VACON NXP Air Cooled series

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

Need this exact configuration or an alternative? Send us the order code 136L3962 or the type code and we will help you find the right drive.

  • Related Products
VACON NXP Air Cooled AC Drive 137L2949

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 525-690V IP00 - 137L2949

The VACON NXP Air Cooled AC Drive with order code 137L2949 and type code NXP10306-A0N0TSG-A1A2B400E5 is a 1000 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR13 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137G5318

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 525-690V IP00 - 137G5318

The VACON NXP Air Cooled AC Drive with order code 137G5318 and type code NXP10306-A0N0SSG-A1A2B50000 is a 1000 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR13 configuration. It is rated...
VACON NXP Air Cooled AC Drive 132L4196

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 525-690V IP00 - 132L4196

The VACON NXP Air Cooled AC Drive with order code 132L4196 and type code NXP10306-A0T0SSG-A1AFBH00E9+FL23 is a 1000 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR13 configuration. It is...
VACON NXP Air Cooled AC Drive 136H5004

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 525-690V IP00 - 136H5004

The VACON NXP Air Cooled AC Drive with order code 136H5004 and type code NXP10306-G0T0TSG-A1A3B4B500+FL26+DLCN is a 1000 kW (1350 HP), three-phase 525-690 V supply, IP00 enclosure, frame FR13...
VACON NXP Air Cooled AC Drive 132X7955

VACON 

VACON NXP Air Cooled AC Drive 1000 kW 525-690V IP00 - 132X7955

The VACON NXP Air Cooled AC Drive with order code 132X7955 and type code NXP10306-A0T0SSG-A1AF0000CP+FL21+DLSE is a 1000 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR13 configuration. It...