<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 137U0907

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137U0907

The VACON NXP Common DC Bus brake chopper unit with order code 137U0907 and type code NXB04166-A0T08SG-A1A20000E9+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137U0537

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U0537

The VACON NXP Common DC Bus active front end unit with order code 137U0537 and type code NXA13005-A0T02SG-A1A2B500E2 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U0609

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137U0609

The VACON NXP Common DC Bus active front end unit with order code 137U0609 and type code NXA01685-G0T02SG-A1A20000EA is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137U0596

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U0596

The VACON NXP Common DC Bus brake chopper unit with order code 137U0596 and type code NXB00725-G2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137U0535

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U0535

The VACON NXP Common DC Bus active front end unit with order code 137U0535 and type code NXA04605-A0T02SG-A1A2B500E2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137U0707

VACON 

VACON NXP Common DC Bus Active Front End Unit 138 kW 380-500V IP00 - 137U0707

The VACON NXP Common DC Bus active front end unit with order code 137U0707 and type code NXA02055-A0T02SG-A1A2D700E9+GRDC+ARFIF106 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137U0668

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U0668

The VACON NXP Common DC Bus brake chopper unit with order code 137U0668 and type code NXB01405-B2T08SV-A8A20000E9+SPXE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus Active Front End Unit 137U0665

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U0665

The VACON NXP Common DC Bus active front end unit with order code 137U0665 and type code NXA04605-B0T02SG-A8A2B500E9+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137U0531

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U0531

The VACON NXP Common DC Bus active front end unit with order code 137U0531 and type code NXA04605-A0T02SG-A1A200B5E9+FL24+DLPL is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137U0518

VACON 

VACON NXP Common DC Bus Active Front End Unit 303 kW 525-690V IP00 - 137U0518

The VACON NXP Common DC Bus active front end unit with order code 137U0518 and type code NXA02616-A0T02SG-A1A200B5EA+FL21+GABV is a 303 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137U0522

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137U0522

The VACON NXP Common DC Bus brake chopper unit with order code 137U0522 and type code NXB01006-A0T08SV-A1A2000000+GANK is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08...
VACON NXP Common DC Bus Active Front End Unit 137U0374

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U0374

The VACON NXP Common DC Bus active front end unit with order code 137U0374 and type code NXA13005-A0T02SG-A1A2B500E9 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • Next