VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 132L3880

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132L3880

The VACON NXP Common DC Bus active front end unit with order code 132L3880 and type code NXA03256-A0T02SG-A1A200B5E9 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132L3702

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132L3702

The VACON NXP Common DC Bus active front end unit with order code 132L3702 and type code NXA13005-G0T02SG-A1A2B500E9+GSNT+DLES+LPC2+SPXV is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 132L3835

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP21 - 132L3835

The VACON NXP Common DC Bus brake chopper unit with order code 132L3835 and type code NXB00526-A2T08SV-A1A200B8E9+GSSE is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Active Front End Unit 132L3500

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132L3500

The VACON NXP Common DC Bus active front end unit with order code 132L3500 and type code NXA02615-A0T02SG-A1A2B500E5+DLIT is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132L3499

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132L3499

The VACON NXP Common DC Bus active front end unit with order code 132L3499 and type code NXA02615-A0T02SG-A1A2B500E5 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132L3442

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132L3442

The VACON NXP Common DC Bus active front end unit with order code 132L3442 and type code NXA03256-A0T02SG-A1A2D7B5E9+GSNT+DLFR+LPC2+SPXV is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 132L3361

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132L3361

The VACON NXP Common DC Bus active front end unit with order code 132L3361 and type code NXA02615-A0T02SG-A1A20000E9+ARFIFF05 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132L3321

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132L3321

The VACON NXP Common DC Bus active front end unit with order code 132L3321 and type code NXA03256-A0T02SG-A1A2D700E9+GSNT+DLFR+LPC2+SPXV is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 132L3099

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132L3099

The VACON NXP Common DC Bus brake chopper unit with order code 132L3099 and type code NXB01446-A0T08SG-A1A2000000+DLFR is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132L2857

VACON 

VACON NXP Common DC Bus Active Front End Unit 1067 kW 525-690V IP00 - 132L2857

The VACON NXP Common DC Bus active front end unit with order code 132L2857 and type code NXA09206-A0T02SG-A1A200B5E9 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 132L2830

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132L2830

The VACON NXP Common DC Bus active front end unit with order code 132L2830 and type code NXA13005-A0T02SG-A1A2000000+FL26 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 132L2598

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132L2598

The VACON NXP Common DC Bus brake chopper unit with order code 132L2598 and type code NXB00225-G2T08SV-A1A2000000+FL26+DLCN+GACS is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...