VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137U4737

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137U4737

The VACON NXP Common DC Bus active front end unit with order code 137U4737 and type code NXA03855-A0T02SG-A1A2B500E9+FL24+GADN is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137U4644

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U4644

The VACON NXP Common DC Bus active front end unit with order code 137U4644 and type code NXA04605-A0T02SG-A1A2B5D2EA+FL23+DLDE+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137U4633

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137U4633

The VACON NXP Common DC Bus brake chopper unit with order code 137U4633 and type code NXB01446-A0T08SG-A1AF00D2E3 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137U4512

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137U4512

The VACON NXP Common DC Bus active front end unit with order code 137U4512 and type code NXA02615-A0T02SG-A1A2D700EC+FL24+GRID+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137U4510

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137U4510

The VACON NXP Common DC Bus active front end unit with order code 137U4510 and type code NXA02615-A0T02SG-A1A2D700E9+FL24+GRID+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 137U4329

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U4329

The VACON NXP Common DC Bus brake chopper unit with order code 137U4329 and type code NXB00455-A2T08SG-A9A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137U4188

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137U4188

The VACON NXP Common DC Bus active front end unit with order code 137U4188 and type code NXA11505-A0T02SG-A1A2D7B1E9+FL24+MASS+ARFIFF03 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137U4307

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U4307

The VACON NXP Common DC Bus active front end unit with order code 137U4307 and type code NXA13005-G0T02SG-A8A2B50000 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U4187

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137U4187

The VACON NXP Common DC Bus active front end unit with order code 137U4187 and type code NXA11505-A0T02SG-A1A2D7B1E9+FL24+ARFIFF05 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137U4125

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137U4125

The VACON NXP Common DC Bus active front end unit with order code 137U4125 and type code NXA03855-A0T02SG-A1A200B5E9+EMAR+LPC2 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137U4138

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP21 - 137U4138

The VACON NXP Common DC Bus brake chopper unit with order code 137U4138 and type code NXB00346-A2T08SV-A1A2B1BHE6+GAKR is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 137U4107

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137U4107

The VACON NXP Common DC Bus active front end unit with order code 137U4107 and type code NXA13005-A0T02SG-A1A2B500E9+GSNT+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...