  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 136Z8690

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 136Z8690

The VACON NXP Common DC Bus active front end unit with order code 136Z8690 and type code NXA02615-A0T02SG-A1A2B5D2EA+FL23+ARFIFF05+DLDE+LPC2 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 136Z9692

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136Z9692

The VACON NXP Common DC Bus brake chopper unit with order code 136Z9692 and type code NXB00875-A2T08SV-A1A2B50000+GSSE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Active Front End Unit 136Z9715

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 136Z9715

The VACON NXP Common DC Bus active front end unit with order code 136Z9715 and type code NXA03256-A0T02SG-A1A2D7E9E6+FL24+GRID+ARFIF106 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 136Z9655

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136Z9655

The VACON NXP Common DC Bus brake chopper unit with order code 136Z9655 and type code NXB00315-G2T08SV-A8A20000E9+SPXE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 136Z8427

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 136Z8427

The VACON NXP Common DC Bus active front end unit with order code 136Z8427 and type code NXA04605-G0T02SG-A1A2A5CP00+FL26+DLCN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 136Z8362

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136Z8362

The VACON NXP Common DC Bus brake chopper unit with order code 136Z8362 and type code NXB00315-G2T08SV-A8A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 136Z8360

VACON 

VACON NXP Common DC Bus Active Front End Unit 138 kW 380-500V IP00 - 136Z8360

The VACON NXP Common DC Bus active front end unit with order code 136Z8360 and type code NXA02055-G0T02SG-A8A2B500E3 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136Z8265

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136Z8265

The VACON NXP Common DC Bus active front end unit with order code 136Z8265 and type code NXA01256-A0T02SG-A1A2D700E9 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Rectifier Unit 136Z8332

VACON 

VACON NXP Common DC Bus Rectifier Unit 410 kW 525-690V IP00 - 136Z8332

The VACON NXP Common DC Bus rectifier unit with order code 136Z8332 and type code NXN06506-X0T0SSV-0000000000+GAMA is a 410 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus Brake Chopper Unit 136Z8288

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136Z8288

The VACON NXP Common DC Bus brake chopper unit with order code 136Z8288 and type code NXB00225-G2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 136Z8047

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 136Z8047

The VACON NXP Common DC Bus brake chopper unit with order code 136Z8047 and type code NXB00315-A2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 136Z8031

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136Z8031

The VACON NXP Common DC Bus active front end unit with order code 136Z8031 and type code NXA10306-A0T02SG-A1A2D7D2E9+ARFIF106 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...