VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137N7681

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137N7681

The VACON NXP Common DC Bus active front end unit with order code 137N7681 and type code NXA02615-A0T02SG-A1A2D7B500+GSNT+DLFR+SPXE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N7721

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137N7721

The VACON NXP Common DC Bus active front end unit with order code 137N7721 and type code NXA03256-A0T02SG-A1A2B50000+ARFIFF02V141+GSNT+GALR+LPC2+SPXE is a 377 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus Brake Chopper Unit 137N7403

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137N7403

The VACON NXP Common DC Bus brake chopper unit with order code 137N7403 and type code NXB03005-A0T08SG-A1A200CI00+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137N7404

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137N7404

The VACON NXP Common DC Bus brake chopper unit with order code 137N7404 and type code NXB02055-A0T08SG-A1A200CI00+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137N7401

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137N7401

The VACON NXP Common DC Bus active front end unit with order code 137N7401 and type code NXA13005-A0T02SG-A1A200CI00+FL23+ARFIFF02V141+DLDE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 137N7399

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137N7399

The VACON NXP Common DC Bus brake chopper unit with order code 137N7399 and type code NXB03855-A0T08SG-A1A200CI00+FL23 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N7339

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137N7339

The VACON NXP Common DC Bus active front end unit with order code 137N7339 and type code NXA10306-A0T02SG-A1A2B50000+GSNT+SPXE is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 137N7204

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP21 - 137N7204

The VACON NXP Common DC Bus brake chopper unit with order code 137N7204 and type code NXB00526-A2T08SV-A1A30000E9+QGLM+GALR is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Active Front End Unit 137N7113

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137N7113

The VACON NXP Common DC Bus active front end unit with order code 137N7113 and type code NXA02615-A0T02SG-A1A2000000+ARFIFF05+LPC2 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137N7011

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137N7011

The VACON NXP Common DC Bus brake chopper unit with order code 137N7011 and type code NXB00875-A2T08SV-A1A20000E9+DLFR+SPXE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Active Front End Unit 137N6832

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N6832

The VACON NXP Common DC Bus active front end unit with order code 137N6832 and type code NXA04605-G0T02SG-A8A2B50000+GADN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N6721

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137N6721

The VACON NXP Common DC Bus active front end unit with order code 137N6721 and type code NXA11505-A0T02SG-A1A200CI00+FL23+ARFIFF02V141+DLDE is a 773 kW, three-phase 380-500 V supply, IP00 enclosure,...