<
<
  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC Drive 137N5795

VACON 

VACON NXP Air Cooled AC Drive 37.5 kW 525-690V IP21 - 137N5795

The VACON NXP Air Cooled AC Drive with order code 137N5795 and type code NXP00416-A2T1SSV-A1AFB50000 is a 37.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N5791

VACON 

VACON NXP Air Cooled AC Drive 22 kW 380-500V IP54 - 137N5791

The VACON NXP Air Cooled AC Drive with order code 137N5791 and type code NXP00455-A5H1SSV-A1A20000E5+QGLM is a 22 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06 configuration. It is...
VACON NXP Air Cooled AC Drive 137N5779

VACON 

VACON NXP Air Cooled AC Drive 90 kW 380-500V IP54 - 137N5779

The VACON NXP Air Cooled AC Drive with order code 137N5779 and type code NXP01685-A5T0SSV-A1A3000000+QGLM is a 90 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR08 configuration. It is...
VACON NXP Air Cooled AC Drive 137N5789

VACON 

VACON NXP Air Cooled AC Drive 22 kW 380-500V IP21 - 137N5789

The VACON NXP Air Cooled AC Drive with order code 137N5789 and type code NXP00455-A2H2SSV-A1A300D2E3+FL21+DLFI is a 22 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Air Cooled AC Drive 137N5790

VACON 

VACON NXP Air Cooled AC Drive 37 kW 380-500V IP54 - 137N5790

The VACON NXP Air Cooled AC Drive with order code 137N5790 and type code NXP00725-A5H1SSV-A1A2BE0000 is a 37 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR07 configuration. It is rated 72...
VACON NXP Air Cooled AC Drive 137N5772

VACON 

VACON NXP Air Cooled AC Drive 630 kW 380-500V IP00 - 137N5772

The VACON NXP Air Cooled AC Drive with order code 137N5772 and type code NXP11505-A0N0SSG-A1B100D6CP+FL24+DLPL is a 630 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR13 configuration. It...
VACON NXP Air Cooled AC Drive 137N5743

VACON 

VACON NXP Air Cooled AC Drive 30 kW 525-690V IP21 - 137N5743

The VACON NXP Air Cooled AC Drive with order code 137N5743 and type code NXP00346-A2T1SSV-A1A3A5E9E6 is a 30 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06 configuration. It is rated 34...
VACON NXP Air Cooled AC Drive 137N5742

VACON 

VACON NXP Air Cooled AC Drive 250 kW 380-500V IP00 - 137N5742

The VACON NXP Air Cooled AC Drive with order code 137N5742 and type code NXP04605-A0N1SSB-A1A2A5B400 is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N5734

VACON 

VACON NXP Air Cooled AC Drive 55 kW 380-500V IP21 - 137N5734

The VACON NXP Air Cooled AC Drive with order code 137N5734 and type code NXP01055-A2T1SSV-A1A2A5B1E3+QGLM+FL26+LS60+GNCT+GNUA+GNEA is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Air Cooled AC Drive 137N5714

VACON 

VACON NXP Air Cooled AC Drive 160 kW 380-500V IP21 - 137N5714

The VACON NXP Air Cooled AC Drive with order code 137N5714 and type code NXP03005-A2H0SSG-A1A30000E9+QGLM+FL23+DPAP+DLDE is a 160 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09...
VACON NXP Air Cooled AC Drive 137N5711

VACON 

VACON NXP Air Cooled AC Drive 3 kW 525-690V IP54 - 137N5711

The VACON NXP Air Cooled AC Drive with order code 137N5711 and type code NXP00046-A5T0SSV-A8A2000000+FL21+DPAP+DLSE is a 3 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06 configuration...
VACON NXP Air Cooled AC Drive 137N5707

VACON 

VACON NXP Air Cooled AC Drive 5.5 kW 380-500V IP21 - 137N5707

The VACON NXP Air Cooled AC Drive with order code 137N5707 and type code NXP00125-A2H2SSV-A9A2000000 is a 5.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated...
  • Previous
  • 669
  • 670
  • 671
  • 672
  • 673
  • 674
  • 675
  • 676
  • 677
  • 678
  • 679
  • Next