VACON 100 INDUSTRIAL Enclosed Drive AC Drive 560 kW 380-500V IP54 - 135X7710
- Brand
- VACON
- SKU:
- 135X7710
- Condition:
- New
- Series:
- VACON 100 INDUSTRIAL Enclosed Drive
- Power (kW):
- 560
- Power (HP):
- 900
- Rated current (A):
- 1040
- Mains voltage:
- 380-500 V
- Enclosure:
- IP54
- Frame size:
- MR12
- EMC category:
- C3
- Brake chopper:
- Yes
- Control panel:
- Graphical Keypad
- Type code:
- VACON0100-3L-1040-5-ED+SCB1+SDB2+SEE9+SRBT+IP54+DBIN+FL03+LS60+DLBR+CAPT+CIFD+PODU+CTID+CACL+CHPH+GNUL
Description
The VACON 100 INDUSTRIAL Enclosed Drive AC Drive with order code 135X7710 and type code VACON0100-3L-1040-5-ED+SCB1+SDB2+SEE9+SRBT+IP54+DBIN+FL03+LS60+DLBR+CAPT+CIFD+PODU+CTID+CACL+CHPH+GNUL is a 560 kW (900 HP), three-phase 380-500 V supply, IP54 enclosure, frame MR12 configuration. It is rated 1040 A continuous output current, meets EMC category C3 and has an integrated brake chopper.
Key specifications
| Order code | 135X7710 |
|---|---|
| Type code | VACON0100-3L-1040-5-ED+SCB1+SDB2+SEE9+SRBT+IP54+DBIN+FL03+LS60+DLBR+CAPT+CIFD+PODU+CTID+CACL+CHPH+GNUL |
| Series | VACON® 100 INDUSTRIAL Enclosed Drive |
| Product type | AC Drive |
| Rated power | 560 kW / 900 HP |
| Power, high overload | 500 kW |
| Rated current | 1040 A |
| Current, high overload | 920 A |
| Mains voltage | 380-500 Vac |
| Phases | Three phase |
| Enclosure | IP54/NEMA12 |
| Frame size | MR12 |
| EMC category | C3 |
| RFI filter | Class A2 |
| Brake chopper | Integrated |
| Control panel | Graphical Keypad |
| Fieldbus | Std protocol,Modbus,N2,BacNet |
| Dimensions (H x W x D) | 2100 x 1212 x 600 mm |
| Net weight | 726.5 kg |
| EAN | 5710108440251 |
Type code configuration
| Option | Code | Selection |
|---|---|---|
| Segment | NONE | VACON 100 Industrial |
| Mains voltage | -5 | 380-500 Vac |
| Current rating | -1040 | 1040 Amp |
| Installation options | -ED | ED Enclosed Drive |
| Enclosure | +IP54 | IP54/NEMA12 |
| Control panel | +HMGR | Graphical Keypad MK01 |
| EMC emission limit category | +EMC3 | C3 Commercial&Industry Environ |
| Brake chopper | +DBIN | Integrated Brake Chopper |
| Real time clock option | +SRBT | Battery for real time clock |
| Configurable power range | NONE | None |
| Power connections | +P000 | No Power options (+P000) |
| Cable entry | +Q000 | No option |
| Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) |
| Additional Equipment C | +Q000 | No additonal option for Qxxx_C |
| Shipping package | +GSWP | Wooden box as shipping pack |
| Marine construction | +E000 | no option |
| B-Slot Option Board | +SBF3 | F3,3 Relay board |
| C- Slot Option Board | +SCB1 | B1,6 programmableDI/DO |
| D-Slot Option Board | +SDB2 | B2,1RO(NO/NC),1RO(NO),therm |
| E-Slot Option Board | +SEE9 | E9,2-port ethernet |
| Internal FB selection | +FBM1 | Std protocol,Modbus,N2,BacNet |
| Documentation level | +DPAP | Paper Manuals |
| Document language preference | +DLBR | Brazilian Portuguese |
| Firmware Language Pack | +FL03 | UK, ES, FR, IT, NL, PT lang |
| Application | +A0000 | No Application |
| Parameter Set | +L0000 | No application parameter set |
| Motor parameter default freq | +LS60 | 60 Hz def motor freq settings |
| Unit for measure for display | +LSSI | Metric Units of Measure |
| Labeling options | +LPC1 | no additional labels |
| UL approval | +GNUL | No Ul Approval (+GNUL) |
| Marine approval | NONE | None |
| RCM Approval | +GACT | RCM Approval N16307 |
| KC approval | +GAKC | KC Approval |
| Ukrainian approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Auxilary power supply | +CAPT | Aux voltage transformer |
| DC power supply for aux device | +C000 | no option |
| AC socket for aux devices | +C000 | no option |
| Input Devices | +CIFD | (+CIFD) Fuse Switch |
| Common mode filter (for ED) | +P000 | no option |
| DU/DT, Sine filter (for ED) | +PODU | dU/dt filter |
| Terminal Options | +CTID | Extended I/O Terminals |
| Door Equipments | +C000 | no option |
| Cabinet heater | +C000 | no option |
| Cabinet light | +CACL | Cabinet light |
| Motor heater control | +C000 | no option |
| Emergency stop options | +C000 | no option |
| Insulation fault sensor | +C000 | no option |
| Cabling from top | +C000 | no option |
| Back channel cooling | +C000 | no option |
| Cabinet Plinth | +CHPH | Base plint 200 mm |
| Empty extension segment | NONE | None |
| Standardized cabinet solution | NONE | None |
| Engineered cabinet solution | NONE | None |
| Product Group | VACON | VACON |
| Product Series | 0100 | Vacon 100 series |
| Phase | -3L | 3 Phase AC Input |
| Customized | +BM26 | Vacon 100 |
| Main Circuit | +M000 | NONE |
| Firmware | +F0072 | Vacon0100 Software package |
| Max output frequency | NONE | None |
| Terminal Box | +T000 | NONE |
| Bypass Control Operation Mode | NONE | none_ |
| Bypass Input Type | NONE | none_ |
| Bypass power connection type | NONE | none_ |
| CE approval | +GACE | CE Approval (+GACE) |
| ATEX Approval | NONE | None |
| County Specific Approval | NONE | None |
| Warranty time | +WT01 | Warranty 12/18 months (+WT01) |
| Frame Size | MR12 | 2xFrame 10 |
| Motor Power Low Overload [kW] | 560 | 560 |
| Motor Power High Overload [kW] | 500 | 500 |
| Dimensions WxHxD [mm] | 1212X2100X600 | 1212X2100X600 |
| Continuous Current (NO) [A] | 1040 | 1040 |
| Continuous Current (HO) [A] | 920 | 920 |
| Motor Power HP Low Overload | 900 | 900 |
| Motor Power HP High Overload | 800 | 800 |
Typical applications
At 560 kW, this AC Drive is typically used for high-power industrial machines and processes where a complete, ready-to-install cabinet drive is needed.
Configuration notes
- IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
- EMC category C3 is intended for industrial (second environment) networks.
- The integrated brake chopper lets you connect an external braking resistor for fast stops and overhauling loads such as cranes and conveyors.
- For heavy-duty use with high overload the rating is 500 kW / 920 A.
- It is supplied with a graphical keypad for local control and parameter setting.
- Built-in communication: Std protocol,Modbus,N2,BacNet.
- Installed option boards: slot B: 3 Relay board; slot C: 6 programmableDI/DO; slot D: 1RO(NO/NC),1RO(NO),therm; slot E: 2-port ethernet.
About the VACON 100 INDUSTRIAL Enclosed Drive series
The VACON® 100 INDUSTRIAL Enclosed Drive is a complete, cabinet-mounted AC drive for demanding industrial applications. Main switch, fuses, cable entries and options are integrated in a robust IP21 or IP54 enclosure that is ready to install.
Need this exact configuration or an alternative? Send us the order code 135X7710 or the type code and we will help you find the right drive.