VACON 100 FLOW Enclosed Drive AC Drive 315 kW 380-500V IP54 - 137L2103
- Brand
- VACON
- SKU:
- 137L2103
- Condition:
- New
- Series:
- VACON 100 FLOW Enclosed Drive
- Power (kW):
- 315
- Power (HP):
- 500
- Rated current (A):
- 590
- Mains voltage:
- 380-500 V
- Enclosure:
- IP54
- Frame size:
- MR10
- EMC category:
- C3
- Brake chopper:
- No
- Control panel:
- Graphical Keypad
- Type code:
- VACON0100-3L-0590-5-ED-FLOW+SBF4+SCB4+SRBT+IP54+FBIE+CAPU+CAPD+CIFD+CDLP+CACH+CAMH+CHCB+EMAR+GNUL
Description
The VACON 100 FLOW Enclosed Drive AC Drive with order code 137L2103 and type code VACON0100-3L-0590-5-ED-FLOW+SBF4+SCB4+SRBT+IP54+FBIE+CAPU+CAPD+CIFD+CDLP+CACH+CAMH+CHCB+EMAR+GNUL is a 315 kW (500 HP), three-phase 380-500 V supply, IP54 enclosure, frame MR10 configuration. It is rated 590 A continuous output current and meets EMC category C3.
Key specifications
| Order code | 137L2103 |
|---|---|
| Type code | VACON0100-3L-0590-5-ED-FLOW+SBF4+SCB4+SRBT+IP54+FBIE+CAPU+CAPD+CIFD+CDLP+CACH+CAMH+CHCB+EMAR+GNUL |
| Series | VACON® 100 FLOW Enclosed Drive |
| Product type | AC Drive |
| Rated power | 315 kW / 500 HP |
| Rated current | 590 A |
| Mains voltage | 380-500 Vac |
| Phases | Three phase |
| Enclosure | IP54/NEMA12 |
| Frame size | MR10 |
| EMC category | C3 |
| RFI filter | Class A2 |
| Brake chopper | Not included |
| Control panel | Graphical Keypad |
| Fieldbus | IndEth (ProfinetIO,EthernetIP) |
| Dimensions (H x W x D) | 2055 x 606 x 639 mm |
| Net weight | 404.2 kg |
| EAN | 5715253491554 |
Type code configuration
| Option | Code | Selection |
|---|---|---|
| Segment | -FLOW | VACON 100 FLOW |
| Mains voltage | -5 | 380-500 Vac |
| Current rating | -0590 | 590 Amp |
| Installation options | -ED | ED Enclosed Drive |
| Enclosure | +IP54 | IP54/NEMA12 |
| Control panel | +HMGR | Graphical Keypad MK01 |
| EMC emission limit category | +EMC3 | C3 Commercial&Industry Environ |
| Brake chopper | +DBNO | No dynamic braking device |
| Real time clock option | +SRBT | Battery for real time clock |
| Configurable power range | NONE | None |
| Power connections | +P000 | No Power options (+P000) |
| Cable entry | +Q000 | No option |
| Additional Equipment B | +Q000 | No option for Qxxx_B (+Q000) |
| Additional Equipment C | +Q000 | No additonal option for Qxxx_C |
| Shipping package | +GSWP | Wooden box as shipping pack |
| Marine construction | +EMAR | Marine construction |
| B-Slot Option Board | +SBF4 | F4,2 Relay board with therm |
| C- Slot Option Board | +SCB4 | B4,AI,2AO(mA,isol),+24V/EXT |
| D-Slot Option Board | +SD00 | No board |
| E-Slot Option Board | +SE00 | No board |
| Internal FB selection | +FBIE | IndEth (ProfinetIO,EthernetIP) |
| Documentation level | +DPAP | Paper Manuals |
| Document language preference | +DLUK | English |
| Firmware Language Pack | +FL01 | UK, DE, FI, SE, IT, FR lang |
| Application | +A0000 | No Application |
| Parameter Set | +L0000 | No application parameter set |
| Motor parameter default freq | +LS50 | 50 Hz def motor freq settings |
| Unit for measure for display | +LSSI | Metric Units of Measure |
| Labeling options | +LPC1 | no additional labels |
| UL approval | +GNUL | No Ul Approval (+GNUL) |
| Marine approval | NONE | None |
| RCM Approval | +GACT | RCM Approval N16307 |
| KC approval | +GAKC | KC Approval |
| Ukrainian approval | +GAUA | Ukrainian Approval |
| EAC Approval | +GAEA | EAC Approval |
| Auxilary power supply | +CAPU | Terminals for aux power supply |
| DC power supply for aux device | +CAPD | 24V DC power supply |
| AC socket for aux devices | +C000 | no option |
| Input Devices | +CIFD | (+CIFD) Fuse Switch |
| Common mode filter (for ED) | +P000 | no option |
| DU/DT, Sine filter (for ED) | +P000 | no option |
| Terminal Options | +CTIO | I/O Terminals |
| Door Equipments | +CDLP | Signal lights and reset button |
| Cabinet heater | +CACH | Cabinet heater |
| Cabinet light | +C000 | no option |
| Motor heater control | +CAMH | Motor heater control |
| Emergency stop options | +C000 | no option |
| Insulation fault sensor | +C000 | no option |
| Cabling from top | +C000 | no option |
| Back channel cooling | +CHCB | Back Channel Cooling |
| Cabinet Plinth | +C000 | no option |
| Empty extension segment | NONE | None |
| Standardized cabinet solution | NONE | None |
| Engineered cabinet solution | NONE | None |
| Product Group | VACON | VACON |
| Product Series | 0100 | Vacon 100 series |
| Phase | -3L | 3 Phase AC Input |
| Customized | +BM2H | Vacon 100-FLOW |
| Main Circuit | +M000 | NONE |
| Firmware | +F0159 | Vacon0100-Flow Software pack |
| Max output frequency | NONE | None |
| Terminal Box | +T000 | NONE |
| Bypass Control Operation Mode | NONE | none_ |
| Bypass Input Type | NONE | none_ |
| Bypass power connection type | NONE | none_ |
| CE approval | +GACE | CE Approval (+GACE) |
| ATEX Approval | NONE | None |
| County Specific Approval | NONE | None |
| Warranty time | +WT01 | Warranty 12/18 months (+WT01) |
| Frame Size | MR10 | Frame 10 |
| Motor Power Low Overload [kW] | 315 | 315 |
| Dimensions WxHxD [mm] net | 606 X 2055 X 639 | 606 X 2055 X 639 |
| Dimensions WxHxD [mm] Gross | 775 X 2435 X 880 | 775 X 2435 X 880 |
| Continuous Current (NO) [A] | 590 | 590 |
| Motor Power HP Low Overload | 500 | 500 |
| STAT NO | 04866 | |
| Variant condition (ref. YV00) | -5-EDMR10+IP54 -5MR10+IP54 -FLOW-5-0590-ED+IP54 -FLOW-5-EDMR10+IP54 -FLOW-5MR10+IP54 0100+DBNOMR10 0100+DPAP 0100+EMC3 0100+FBIE 0100+HMGR 0100+L0000MR10 0100+P000MR10 0100+Q000MR10 0100+SBF4 0100+SCB4 0100+SD00 0100+SE00 0100+SRBT 0100+WT01 0100-0590-5-ED+CIFD 0100-ED+C000 0100-ED+C000MR10 0100-ED+CACHMR10 0100-ED+CAMH 0100-ED+CAPD 0100-ED+CAPU 0100-ED+CDLP 0100-ED+CHCBMR10 0100-ED+CIFDMR10 0100-ED+CTIO 0100-ED+EMARMR10 0100-ED+GSWPMR10 0100-ED+P000MR10 0100-EDMR10NONE 0100-EDNONE 04866 PILOT VACON VACON0100 VACON0100-5 VACON0100-5MR10 VACON0100-FLOW VACON0100-FLOW-5 VACON0100-FLOW-5-ED VACON0100-FLOW-5MR10 VACON0100-FLOW-ED VACON0100-FLOW-EDMR10 VACON0100-FLOWMR10 VACON0100MR10 VACON0100MR10+IP54 | |
| Variant condition (Purch) | -5-EDMR10+IP54 -5MR10+IP54 -FLOW-5-0590-ED+IP54 -FLOW-5-EDMR10+IP54 -FLOW-5MR10+IP54 0100+DBNOMR10 0100+DPAP 0100+EMC3 0100+FBIE 0100+HMGR 0100+L0000MR10 0100+P000MR10 0100+Q000MR10 0100+SBF4 0100+SCB4 0100+SD00 0100+SE00 0100+SRBT 0100+WT01 0100-0590-5-ED+CIFD 0100-ED+C000 0100-ED+C000MR10 0100-ED+CACHMR10 0100-ED+CAMH 0100-ED+CAPD 0100-ED+CAPU 0100-ED+CDLP 0100-ED+CHCBMR10 0100-ED+CIFDMR10 0100-ED+CTIO 0100-ED+EMARMR10 0100-ED+GSWPMR10 0100-ED+P000MR10 0100-EDMR10NONE 0100-EDNONE 04866 PILOT VACON VACON0100 VACON0100-5 VACON0100-5MR10 VACON0100-FLOW VACON0100-FLOW-5 VACON0100-FLOW-5-ED VACON0100-FLOW-5MR10 VACON0100-FLOW-ED VACON0100-FLOW-EDMR10 VACON0100-FLOWMR10 VACON0100MR10 VACON0100MR10+IP54 | |
| Method | HORIZONTAL | HORIZONTAL |
Typical applications
At 315 kW, this AC Drive is typically used for high-power pumps and fans where a complete, ready-to-install cabinet drive is needed.
Configuration notes
- IP54 / UL Type 12 protects against dust and splashing water for mounting directly in production areas.
- EMC category C3 is intended for industrial (second environment) networks.
- There is no integrated brake chopper; for fast braking use an external braking unit or a regenerative solution.
- It is supplied with a graphical keypad for local control and parameter setting.
- Built-in communication: IndEth (ProfinetIO,EthernetIP).
- Installed option boards: slot B: 2 Relay board with therm; slot C: AI,2AO(mA,isol),+24V/EXT.
About the VACON 100 FLOW Enclosed Drive series
The VACON® 100 FLOW Enclosed Drive is a factory-built, cabinet-mounted AC drive for pumps and fans. It is delivered ready to install with main switch, fuses, cable entries and optional filters, reducing engineering and installation time on site.
Need this exact configuration or an alternative? Send us the order code 137L2103 or the type code and we will help you find the right drive.