<
<
  • Search

Drives

  • Home
  • Drives

Drives

Vacon AC drives (variable frequency drives) for every application: VACON 100 INDUSTRIAL, 100 FLOW, 100 HVAC, 100 X, VACON 20, NXS, NXP and NXC. Browse by series and supply voltage, compare power, enclosure and frame size, and send an inquiry for any order code or type code.

Choose a range

VACON 100 INDUSTRIAL

VACON 100 INDUSTRIAL

VACON 100 FLOW

VACON 100 FLOW

VACON 100 HVAC

VACON 100 HVAC

VACON 100 X

VACON 100 X

VACON 20

VACON 20

VACON 20 X

VACON 20 X

VACON 20 Cold Plate

VACON 20 Cold Plate

VACON NXS

VACON NXS

VACON NXC

VACON NXC

VACON NXP

VACON NXP

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-G0T02SG-A1A3B1B5E9 137U0856 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0856 and type code NXA01685-G0T02SG-A1A3B1B5E9+ARFIFF05+DNOT is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-G0T02SG-A8B1D7D2E9 137U1082 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U1082 and type code NXA03855-G0T02SG-A8B1D7D2E9+ARFIFF03 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-A0T08SG-A1A2000000 137U0806 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137U0806 and type code NXB04166-A0T08SG-A1A2000000+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-A0T08SG-A1A20000E9 137U0907 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137U0907 and type code NXB04166-A0T08SG-A1A20000E9+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A2B500E2 137U0537 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0537 and type code NXA13005-A0T02SG-A1A2B500E2 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-G0T02SG-A1A20000EA 137U0609 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0609 and type code NXA01685-G0T02SG-A1A20000EA is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB00725-G2T08SV-A1A2000000 137U0596 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 137U0596 and type code NXB00725-G2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B500E2 137U0535 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0535 and type code NXA04605-A0T02SG-A1A2B500E2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02055-A0T02SG-A1A2D700E9 137U0707 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0707 and type code NXA02055-A0T02SG-A1A2D700E9+GRDC+ARFIF106 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FR08, IP21

VACON 

NXB01405-B2T08SV-A8A20000E9 137U0668 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 137U0668 and type code NXB01405-B2T08SV-A8A20000E9+SPXE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-B0T02SG-A8A2B500E9 137U0665 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0665 and type code NXA04605-B0T02SG-A8A2B500E9+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A200B5E9 137U0531 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U0531 and type code NXA04605-A0T02SG-A1A200B5E9+FL24+DLPL is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
  • Previous
  • 514
  • 515
  • 516
  • 517
  • 518
  • 519
  • 520
  • 521
  • 522
  • 523
  • 524
  • Next