  • Search

VACON NXP Liquid Cooled Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

VACON® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

VACON® NXP Liquid Cooled Common DC Bus: technical overview

Easy integration – ultimate flexibility

With one of the best power/size ratios, VACON® NXP Liquid Cooled drives are ideal for applications where space is at a premium or air cooling is difficult. Heavy industries with harsh operating conditions, such as in marine, offshore and mining environments benefit from the drive’s compact design and robust reliability.

The VACON® NXP range of common Liquid Cooled DC bus drive products includes front-end units, inverters and brake-chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

As a high degree of protection (IP54 or higher) can easily be achieved with these drives, they can be installed almost anywhere in a plant or on a vessel. This eliminates the load on air-conditioning systems in electrical rooms reducing costs and installation time, and makes them ideal for retrofitting.

 

Supply voltages and power range 

3 x 400-500 V...7.5-4100 kW
3 x 525-690 V...110-5300 kW

 

Features and benefits

  • Reduced energy costs as regenerative filter feeds excess braking energy back into network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications 

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Liquid Cooled Common DC Bus 380-500 V

VACON NXP Liquid Cooled Common DC Bus 380-500 V

VACON NXP Liquid Cooled Common DC Bus 525-690 V

VACON NXP Liquid Cooled Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH64, IP00

VACON 

NXA17006-A0T02WG-A1AFD700E6 137N7821 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1796 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N7821 and type code NXA17006-A0T02WG-A1AFD700E6+FL23+GRID+ARFIF106+DLDE is a 1796 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH64, IP00

VACON 

NXA17006-A0T02WG-ANA200B5E9 137N7970 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1796 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N7970 and type code NXA17006-A0T02WG-ANA200B5E9+ARFIFF03 is a 1796 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH64, IP00

VACON 

NXA20605-A0T02PG-A8A20000E9 137N7682 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1262 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N7682 and type code NXA20605-A0T02PG-A8A20000E9+FL28+ARFIFF05+GSNT+LPC2+SPXE is a 1262 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137N7604

VACON 

NXB01706-A0T08WG-A8A20000E9 137N7604 – VACON NXP Liquid Cooled Common DC Bus Brake Chopper Unit, 282 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137N7604 and type code NXB01706-A0T08WG-A8A20000E9+GSNT+GAAB+SPXE is a 282 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N7299

VACON 

NXA04605-A0T02WG-A1A2D7B8EA 137N7299 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 282 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N7299 and type code NXA04605-A0T02WG-A1A2D7B8EA+MASG+ARFIFF03 is a 282 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH05, IP00

VACON 

NXB02615-A0T08WV-A8A20000E3 137N6687 – VACON NXP Liquid Cooled Common DC Bus Brake Chopper Unit, 281 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137N6687 and type code NXB02615-A0T08WV-A8A20000E3+GAAB is a 281 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH64, IP00

VACON 

NXA23005-A0T02WG-A8B1D7D2E3 137N6686 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1409 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N6686 and type code NXA23005-A0T02WG-A8B1D7D2E3+ARFIFF03+GAAB is a 1409 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH64, IP00

VACON 

NXA17008-A0T02WG-A8B1D7E3D2 137N6586 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1796 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N6586 and type code NXA17008-A0T02WG-A8B1D7E3D2+GSNT+SPXE is a 1796 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH63, IP00

VACON 

NXA08205-A0T02WG-A1A2B50000 137N5975 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 502 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N5975 and type code NXA08205-A0T02WG-A1A2B50000 is a 502 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH63, IP00

VACON 

NXA10305-A0T02WG-A8B100D2E3 137N6685 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 631 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N6685 and type code NXA10305-A0T02WG-A8B100D2E3+ARFIFF03+GAAB is a 631 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137N5787

VACON 

NXA05205-A0T02WG-A1A2D700E9 137N5787 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 319 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N5787 and type code NXA05205-A0T02WG-A1A2D700E9+GRID+ARFIF106 is a 319 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus AC drive, frame CH05, IP00

VACON 

NXA02615-G0T02WV-A8A3D700E9 137N5755 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 160 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137N5755 and type code NXA02615-G0T02WV-A8A3D700E9+MASG+ARFIFF03 is a 160 kW, three-phase 380-500 V...
  • Previous
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • Next