VACON NXP Grid Converter

VACON® NXP Grid Converters connect generators, energy storage and renewable sources to the grid or to an island network. They control voltage and frequency, support shore connection and micro-grids, and keep harmonic distortion low.

VACON® NXP Grid Converter: technical overview

Cleaner power for ships and ports

The VACON® NXP Grid Converter is an alternative source of marine power technology that plays a key role in reducing fuel intake and improving efficiency. It can be applied to power generation for ship engines and harbor power supplies to meet the demands of governments and port authorities.

When used with a shore-supply solution, VACON NXP Grid Converter allows electrical power to be sourced from the local grid via a set of cables, rather than the ship’s main engine or generators. This process, sometimes known as ‘cold ironing’, has a significantly positive impact on fuel economy. It causes reductions in CO2, NOx and SOx emissions, as well as noise and vibration levels.

VACON NXP Grid Converter can also be applied to shaft-generator solutions, ensuring that propulsion machinery is able to operate at various speeds. The shaft generator decouples shaft RPMs from the electricity (frequency) which allows better electrical quality and improved fuel economy. Additionally, power can either be taken from or entered into the propeller shaft. This is particularly useful for ships that often alternate their speeds as it creates fuel savings and minimizes exhaust emissions by up to 15%. It also creates an emergency mode meaning that the vessel can operate even if the main engine fails.

 

Supply voltages and power range 

Air cooled:

3 x 380-500 V...180-1100 kW

3 x 525-690 V...200-1200 kW

Liquid cooled:

3 x 400-500 V...160-1800 kW

3 x 525-690 V...210-1800 kW

 

Features and benefits

  • Reduced fuel consumption as electrical power can be sourced from the grid
  • Lower CO2, NOx and SOx emissions as the main engine can be shut down
  • Conforms to ABS and DNV standards
  • Improved energy efficiency as engine speed can be optimized
  • Liquid and air cooled solutions available

 

Applications 

Shaft generators and shore-supply systems.

Choose a range

VACON NXP Grid Converter 380-500 V

VACON NXP Grid Converter 380-500 V

VACON NXP Grid Converter 525-690 V

VACON NXP Grid Converter 525-690 V

View as:
Sidebar
VACON NXP Grid Converter Inverter Unit 132X9370

VACON 

NXI22506-A0T0ISG-A1A2D7D6E5 132X9370 – VACON NXP Grid Converter Inverter Unit, 2000 kW, 525-690V, IP00

The VACON NXP Grid Converter inverter unit with order code 132X9370 and type code NXI22506-A0T0ISG-A1A2D7D6E5+MASG+ARFIFF03 is a 2000 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI14...
VACON NXP Grid Converter Active Front End Unit 132X9340

VACON 

NXA01706-A0T02SG-A1A2D7B1E9 132X9340 – VACON NXP Grid Converter Active Front End Unit, 197 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132X9340 and type code NXA01706-A0T02SG-A1A2D7B1E9+MASG+ARFIFF03+DLES is a 197 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Grid Converter Inverter Unit 132X8946

VACON 

NXI01405-A2T0CSV-A1AFD700E9 132X8946 – VACON NXP Grid Converter Inverter Unit, 75 kW, 380-500V, IP21

The VACON NXP Grid Converter inverter unit with order code 132X8946 and type code NXI01405-A2T0CSV-A1AFD700E9+MASG+ARFIFF03+DLFR is a 75 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Grid Converter Inverter Unit 132X8873

VACON 

NXI14505-A0T0ISG-A1A2D7B5E9 132X8873 – VACON NXP Grid Converter Inverter Unit, 800 kW, 380-500V, IP00

The VACON NXP Grid Converter inverter unit with order code 132X8873 and type code NXI14505-A0T0ISG-A1A2D7B5E9+MASG+ARFIFF03 is a 800 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Grid Converter Inverter Unit 132X8866

VACON 

NXI00455-A2T0CSV-A1A2D70000 132X8866 – VACON NXP Grid Converter Inverter Unit, 22 kW, 380-500V, IP21

The VACON NXP Grid Converter inverter unit with order code 132X8866 and type code NXI00455-A2T0CSV-A1A2D70000+MASG+ARFIFF03 is a 22 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Grid Converter Inverter Unit 132X8688

VACON 

NXI00225-A2T0CSV-A1A20000E9 132X8688 – VACON NXP Grid Converter Inverter Unit, 11 kW, 380-500V, IP21

The VACON NXP Grid Converter inverter unit with order code 132X8688 and type code NXI00225-A2T0CSV-A1A20000E9+MASG+ARFIFF03 is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Grid Converter Inverter Unit 132X8471

VACON 

NXI00455-A2T0CSV-A1A2A50000 132X8471 – VACON NXP Grid Converter Inverter Unit, 22 kW, 380-500V, IP21

The VACON NXP Grid Converter inverter unit with order code 132X8471 and type code NXI00455-A2T0CSV-A1A2A50000+MASG+ARFIFF03 is a 22 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Grid Converter Inverter Unit 132X8585

VACON 

NXI03005-A0T0ISG-A1A2D700E9 132X8585 – VACON NXP Grid Converter Inverter Unit, 160 kW, 380-500V, IP00

The VACON NXP Grid Converter inverter unit with order code 132X8585 and type code NXI03005-A0T0ISG-A1A2D700E9+MASG+ARFIFF03+GSNT+GALR+LPC2+SPXE is a 160 kW, three-phase 380-500 V supply, IP00...
VACON NXP Grid Converter Active Front End Unit 132X7823

VACON 

NXA10306-A0T02SG-A1A2D7B1E9 132X7823 – VACON NXP Grid Converter Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132X7823 and type code NXA10306-A0T02SG-A1A2D7B1E9+MASG+ARFIFF03 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Grid Converter Active Front End Unit 132X7822

VACON 

NXA10306-A0T02SG-A1A2D7B1E9 132X7822 – VACON NXP Grid Converter Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132X7822 and type code NXA10306-A0T02SG-A1A2D7B1E9+MASG+ARFIFF03+LS60 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Grid Converter Active Front End Unit 132X7821

VACON 

NXA09206-A0T02SG-A1A2D7B1E9 132X7821 – VACON NXP Grid Converter Active Front End Unit, 1067 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132X7821 and type code NXA09206-A0T02SG-A1A2D7B1E9+MASG+ARFIFF03+LS60 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Grid Converter Inverter Unit 132X7820

VACON 

NXI09206-A0T0ISG-A1A2D7B1E9 132X7820 – VACON NXP Grid Converter Inverter Unit, 900 kW, 525-690V, IP00

The VACON NXP Grid Converter inverter unit with order code 132X7820 and type code NXI09206-A0T0ISG-A1A2D7B1E9+MASG+ARFIFF03+LS60 is a 900 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • Next