  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B50000 132H1828 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H1828 and type code NXA04605-A0T02SG-A1A2B50000+GSNT+DLFR+GADN+SPXC is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B50000 132H1829 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H1829 and type code NXA04605-A0T02SG-A1A2B50000+GSNT+GALR+SPXC is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2B50000 132H1827 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H1827 and type code NXA02615-A0T02SG-A1A2B50000+GSNT+DLFR+GAAB+SPXC is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A200D6E9 132H1705 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H1705 and type code NXA10306-A0T02SG-A1A200D6E9 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A200D2E9 132H1512 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H1512 and type code NXA10306-A0T02SG-A1A200D2E9 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A2B5E9E5 132H1734 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H1734 and type code NXA10306-A0T02SG-A1A2B5E9E5+SPXE is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2B5D2EA 132H1729 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H1729 and type code NXA02615-A0T02SG-A1A2B5D2EA+FL23+ARFIFF05+DLDE+LPC2+SPXE is a 175 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03855-A0T08SG-A800000000 132H1469 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132H1469 and type code NXB03855-A0T08SG-A800000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-A0T08SG-A1A2000000 132H1480 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132H1480 and type code NXB04166-A0T08SG-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXN06506-X0T0NSV-0000000000 132H1196 – VACON NXP Common DC Bus Rectifier Unit, 410 kW, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 132H1196 and type code NXN06506-X0T0NSV-0000000000+LS60 is a 410 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB01685-A0T08SG-A800000000 132H1465 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132H1465 and type code NXB01685-A0T08SG-A800000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-G0T02SG-A8A2B50000 132H0946 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H0946 and type code NXA01685-G0T02SG-A8A2B50000 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
  • Previous
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • Next