  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA09206-A0T02SG-A1A2D700EC 132L0008 – VACON NXP Common DC Bus Active Front End Unit, 1067 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L0008 and type code NXA09206-A0T02SG-A1A2D700EC+ARFIF106 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXN06506-X0T0SSV-0000000000 132H9745 – VACON NXP Common DC Bus Rectifier Unit, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 132H9745 and type code NXN06506-X0T0SSV-0000000000+DNOT is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1A20000E9 132H9220 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H9220 and type code NXA11505-A0T02SG-A1A20000E9+GSNT+LPC2+SPXE is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1A20000E9 132H9088 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H9088 and type code NXA11505-A0T02SG-A1A20000E9+GSNT+GNUA+LPC2+SPXE is a 773 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2000000 132H8458 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H8458 and type code NXA04605-A0T02SG-A1A2000000+DLIT is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A2B50000 132H8730 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H8730 and type code NXA03256-A0T02SG-A1A2B50000+GSNT+GNUA+GNEA+LPC2+SPXV is a 377 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-G0T02SG-A1A2B50000 132H8418 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H8418 and type code NXA03256-G0T02SG-A1A2B50000+FL26+GSNT+DLRU+LPC2+SPXV is a 377 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-A0T02SG-A1A2B50000 132H8391 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H8391 and type code NXA03855-A0T02SG-A1A2B50000+GSNT+GALR+LPC2+SPXE is a 259 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXN06506-X0T0SSV-0000000000 132H8353 – VACON NXP Common DC Bus Rectifier Unit, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 132H8353 and type code NXN06506-X0T0SSV-0000000000+LS60+GNUL+GNCT+GNKC+GNUA+GNEA is a 650 A, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-G0T02SG-A1A2D70000 132H8267 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H8267 and type code NXA11505-G0T02SG-A1A2D70000+FL26+ARFIFF03+DLCN is a 773 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-G0T02SG-A1A2000000 132H8265 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H8265 and type code NXA11505-G0T02SG-A1A2000000+FL26+ARFIFF30+DLCN is a 773 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB05205-A0T08SG-A1A2000000 132H8227 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132H8227 and type code NXB05205-A0T08SG-A1A2000000+GSNT+LPC2+SPXV is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...