<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXB11806-G0T08SG-A1A2000000 132L1281 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L1281 and type code NXB11806-G0T08SG-A1A2000000+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-A0T02SG-A1A2D700E9 132L1248 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L1248 and type code NXA01685-A0T02SG-A1A2D700E9+FL23+GRDC+ARFIF106 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB00725-G2T08SV-A800000000 132L1103 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132L1103 and type code NXB00725-G2T08SV-A800000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2D700E6 132L0847 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L0847 and type code NXA02615-A0T02SG-A1A2D700E6+FL24+GRID+ARFIF106+DLCZ is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2D7B5E3 132L0748 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L0748 and type code NXA04605-A0T02SG-A1A2D7B5E3+ARFIFF03 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132L0770

VACON 

NXB00455-A2T08SV-A1A20000E9 132L0770 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132L0770 and type code NXB00455-A2T08SV-A1A20000E9+QGLM is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2000000 132L0747 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L0747 and type code NXA04605-A0T02SG-A1A2000000+ARFIFF03 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-A0T02SG-A1A2000000 132L0530 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L0530 and type code NXA01685-A0T02SG-A1A2000000+ARFIF106 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FR04, IP21

VACON 

NXB00125-A2T08SV-A1A20000E9 132L0352 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132L0352 and type code NXB00125-A2T08SV-A1A20000E9+QGLM+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03256-G0T08SG-A1B50000CP 132L0220 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L0220 and type code NXB03256-G0T08SG-A1B50000CP+FL26+DLCN+GACS is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A2B50000 132L0019 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L0019 and type code NXA03256-A0T02SG-A1A2B50000+LS60+GSNT+LPC2+SPXV is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2000000 132H9494 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132H9494 and type code NXA04605-A0T02SG-A1A2000000+FL21+DNOT is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
  • Previous
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • Next