VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-A0T02SG-A1A2000000 132L8685 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L8685 and type code NXA03855-A0T02SG-A1A2000000+ARFIF106 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02055-A0T02SG-A1A200D6E9 132L8176 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L8176 and type code NXA02055-A0T02SG-A1A200D6E9 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-A0T02SG-A1A2D7D2E9 132L7735 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L7735 and type code NXA03855-A0T02SG-A1A2D7D2E9+UGRD+ARFIF106+DLFR is a 259 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A8A2D7B2CI 132L7575 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L7575 and type code NXA03256-A0T02SG-A8A2D7B2CI+ARFIFF03 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02055-A0T02SG-A1A2B50000 132L7431 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L7431 and type code NXA02055-A0T02SG-A1A2B50000 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-A0T02SG-A1A2B50000 132L7559 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L7559 and type code NXA01685-A0T02SG-A1A2B50000 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A200B5E9 132L7285 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L7285 and type code NXA02615-A0T02SG-A1A200B5E9 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB03005-A0T08SG-A1B1A5B8E9 132L7003 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L7003 and type code NXB03005-A0T08SG-A1B1A5B8E9+DLES is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A20000CI 132L7280 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L7280 and type code NXA02615-A0T02SG-A1A20000CI+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1B1A7B8E9 132L6996 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L6996 and type code NXA11505-A0T02SG-A1B1A7B8E9+ARFIFF05+DLES is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB01685-A0T08SG-A1A20000E9 132L6882 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L6882 and type code NXB01685-A0T08SG-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus AC drive, frame FR08, IP00

VACON 

NXB01405-A0T08SV-A8A20000CP 132L6816 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L6816 and type code NXB01405-A0T08SV-A8A20000CP is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08 configuration. It...