  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FR08, IP21

VACON 

NXB01006-G2T08SV-A1A2000000 132N0096 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132N0096 and type code NXB01006-G2T08SV-A1A2000000+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FR08, IP00

VACON 

NXB01405-A0T08SV-A8A2000000 132L9935 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9935 and type code NXB01405-A0T08SV-A8A2000000+FL26+DLCN is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A8A2B5E900 132L9931 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L9931 and type code NXA04605-A0T02SG-A8A2B5E900+FL26+DLCN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB01256-G0T08SG-A1A2000000 132L9875 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9875 and type code NXB01256-G0T08SG-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXN06506-X0T0SSV-0000000000 132L9874 – VACON NXP Common DC Bus Rectifier Unit, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 132L9874 and type code NXN06506-X0T0SSV-0000000000+GNKC is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03856-A0T08SG-A1A3000000 132L9815 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9815 and type code NXB03856-A0T08SG-A1A3000000+FL24 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB03005-A0T08SG-A1B1A5B8E9 132L9382 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9382 and type code NXB03005-A0T08SG-A1B1A5B8E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A2D700E9 132L9760 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L9760 and type code NXA03256-A0T02SG-A1A2D700E9+GRID+ARFIF106 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1B1A7B8E9 132L9381 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L9381 and type code NXA11505-A0T02SG-A1B1A7B8E9+ARFIFF05 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04605-A0T08SG-A1A20000E9 132L8821 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L8821 and type code NXB04605-A0T08SG-A1A20000E9+FL23 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A2D7D2E9 132L8822 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L8822 and type code NXA13005-A0T02SG-A1A2D7D2E9+FL24+GRID+ARFIF106+DLCZ is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03856-A0T08SG-A1A2000000 132L8506 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L8506 and type code NXB03856-A0T08SG-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
  • Previous
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • Next