VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 132N2765

VACON 

NXB00346-A2T08SV-A1A20000E9 132N2765 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132N2765 and type code NXB00346-A2T08SV-A1A20000E9+QGLM+GABV is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02055-A0T02SG-A1A2D7E9CP 132N2749 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N2749 and type code NXA02055-A0T02SG-A1A2D7E9CP+GRID+ARFIF106+DNOT+DLDE is a 138 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A20000E9 132N2568 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N2568 and type code NXA13005-A0T02SG-A1A20000E9+ARFIFF05 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-G0T02SG-A8A2000000 132N2055 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N2055 and type code NXA03855-G0T02SG-A8A2000000 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03855-G0T08SG-A1A2000000 132N2279 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N2279 and type code NXB03855-G0T08SG-A1A2000000+FL26+DLCN is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01446-A0T02SG-A1A200B9E9 132N1942 – VACON NXP Common DC Bus Active Front End Unit, 167 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N1942 and type code NXA01446-A0T02SG-A1A200B9E9+DLES is a 167 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A200B9E9 132N1945 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N1945 and type code NXA03256-A0T02SG-A1A200B9E9+DLES is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA02616-A0T02SG-A1A200B9E9 132N1944 – VACON NXP Common DC Bus Active Front End Unit, 303 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N1944 and type code NXA02616-A0T02SG-A1A200B9E9+DLES is a 303 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FR08, IP00

VACON 

NXB01405-A0T08SV-A800000000 132N1566 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N1566 and type code NXB01405-A0T08SV-A800000000+FL26+DLCN is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A8A3B5E900 132N1562 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N1562 and type code NXA04605-A0T02SG-A8A3B5E900+FL26+DLCN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-G0T02SG-A8A2000000 132N1197 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N1197 and type code NXA03855-G0T02SG-A8A2000000+FL26 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-G0T02SG-A8B4B50000 132N1203 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N1203 and type code NXA02615-G0T02SG-A8B4B50000 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...