VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-A0T02SG-A1A20000E6 132N5190 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N5190 and type code NXA01685-A0T02SG-A1A20000E6+ARFIFF05 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A200B5E9 132N5048 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N5048 and type code NXA04605-A0T02SG-A1A200B5E9 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132N4777

VACON 

NXB00385-A2T08SV-A1A20000E9 132N4777 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132N4777 and type code NXB00385-A2T08SV-A1A20000E9+QGLM is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A200B5E9 132N4676 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N4676 and type code NXA03256-A0T02SG-A1A200B5E9+FL23+ARFIFF05+DLDE is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-A0T02SG-A1A2B50000 132N4451 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N4451 and type code NXA03855-A0T02SG-A1A2B50000+FL23+ARFIFF05+GSNT+GALR+LPC2+SPXV is a 259 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-G0T02SG-A1AFD7B5E9 132N4053 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N4053 and type code NXA02615-G0T02SG-A1AFD7B5E9+FL21+GRID+ARFIF106+DLSE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-A0T02SG-A1A2B50000 132N4176 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N4176 and type code NXA01685-A0T02SG-A1A2B50000+GANK+LPC2 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FR04, IP21

VACON 

NXB00045-A2T08SV-A1A2000000 132N3875 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132N3875 and type code NXB00045-A2T08SV-A1A2000000+QGLM+DNOT is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2D7B5E9 132N3545 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N3545 and type code NXA04605-A0T02SG-A1A2D7B5E9+GRID+ARFIF106 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A200B5E9 132N3486 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N3486 and type code NXA13005-A0T02SG-A1A200B5E9 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2D7E6CP 132N2878 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N2878 and type code NXA02615-A0T02SG-A1A2D7E6CP+UGRD+ARFIF106+DNOT+DLDE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB03005-A0T08SG-A8B1000000 132N2779 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N2779 and type code NXB03005-A0T08SG-A8B1000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...