  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-G0T02SG-A1A2B50000 132N7550 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N7550 and type code NXA04605-G0T02SG-A1A2B50000+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B200E9 132N7534 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N7534 and type code NXA04605-A0T02SG-A1A2B200E9 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A2D7D2E9 132N7397 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N7397 and type code NXA03256-A0T02SG-A1A2D7D2E9+FL24+GRDC+ARFIF106 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB02616-A0T08SG-A1A2000000 132N7164 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N7164 and type code NXB02616-A0T08SG-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA02616-A0T02SG-A1A2B500E9 132N7526 – VACON NXP Common DC Bus Active Front End Unit, 303 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N7526 and type code NXA02616-A0T02SG-A1A2B500E9 is a 303 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01446-A0T02SG-A8A200B1E9 132N6268 – VACON NXP Common DC Bus Active Front End Unit, 167 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N6268 and type code NXA01446-A0T02SG-A8A200B1E9+ARFIFF05+GSNT+DLES+GABV+LPC2+SPXV is a 167 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2000000 132N6351 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N6351 and type code NXA04605-A0T02SG-A1A2000000+FL25+DLES is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03855-A0T02SG-A1A2B500E9 132N6224 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N6224 and type code NXA03855-A0T02SG-A1A2B500E9+FL23+GSNT+GABV+LPC2+SPXV is a 259 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Brake Chopper Unit 132N6410

VACON 

NXB00315-A2T08SV-A1A200E9E9 132N6410 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132N6410 and type code NXB00315-A2T08SV-A1A200E9E9+EMAR is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB04166-A0T08SG-A1A20000E9 132N6898 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N6898 and type code NXB04166-A0T08SG-A1A20000E9+GSNT+LPC2+SPXV is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A2B50000 132N7110 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N7110 and type code NXA10306-A0T02SG-A1A2B50000+ARFIF106 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A3000000 132N6915 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N6915 and type code NXA10306-A0T02SG-A1A3000000 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • Next