<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01706-A0T02SG-A1A2000000 132X7795 – VACON NXP Common DC Bus Active Front End Unit, 197 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X7795 and type code NXA01706-A0T02SG-A1A2000000+FL23+DLNL is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA09206-A0T02SG-A1A2D700CP 132X7815 – VACON NXP Common DC Bus Active Front End Unit, 1067 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X7815 and type code NXA09206-A0T02SG-A1A2D700CP+GRDC+ARFIF106 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2D7BHE9 132X7745 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X7745 and type code NXA02615-A0T02SG-A1A2D7BHE9+GRID+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA09206-A0T02SG-A1A2D700E9 132X7662 – VACON NXP Common DC Bus Active Front End Unit, 1067 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X7662 and type code NXA09206-A0T02SG-A1A2D700E9+GRDC+ARFIF106 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03855-A0T08SG-A8A20000E9 132X7425 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132X7425 and type code NXB03855-A0T08SG-A8A20000E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03855-A0T08SG-A8A20000E9 132X7424 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132X7424 and type code NXB03855-A0T08SG-A8A20000E9+GACS is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FR07, IP21

VACON 

NXB00875-A2T08SV-A1A2000000 132X7333 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132X7333 and type code NXB00875-A2T08SV-A1A2000000+QGLM+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus AC drive, frame FR08, IP21

VACON 

NXB01405-A2T08SV-A1A20000E9 132X7306 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132X7306 and type code NXB01405-A2T08SV-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB01706-A0T08SG-A1A2000000 132X7157 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132X7157 and type code NXB01706-A0T08SG-A1A2000000+EMAR is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB02615-A0T08SG-A1A20000E9 132X7127 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132X7127 and type code NXB02615-A0T08SG-A1A20000E9+FL23 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A8A2B50000 132X7033 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X7033 and type code NXA04605-A0T02SG-A8A2B50000+ARFIFF05+GSNT+GABV+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A8A2B50000 132X7031 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132X7031 and type code NXA13005-A0T02SG-A8A2B50000+ARFIFF05+GSNT+GABV+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
  • Previous
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • Next