<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01706-A0T02SG-A1A2B50000 136L0895 – VACON NXP Common DC Bus Active Front End Unit, 197 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136L0895 and type code NXA01706-A0T02SG-A1A2B50000 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB02615-A0T08SG-A1A20000E9 136L0285 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 136L0285 and type code NXB02615-A0T08SG-A1A20000E9+DLES is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB02615-A0T08SG-A1A20000E9 136L0747 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 136L0747 and type code NXB02615-A0T08SG-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03855-A0T08SG-A1A2000000 136H9937 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 136H9937 and type code NXB03855-A0T08SG-A1A2000000+FL23 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A2000000 136H9445 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H9445 and type code NXA13005-A0T02SG-A1A2000000+FL23 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A2000000 136H9785 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H9785 and type code NXA10306-A0T02SG-A1A2000000 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2000000 136H9358 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H9358 and type code NXA02615-A0T02SG-A1A2000000 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2000000 136H9155 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H9155 and type code NXA04605-A0T02SG-A1A2000000+DLES is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A200D2CP 136H8905 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H8905 and type code NXA13005-A0T02SG-A1A200D2CP is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA13005-A0T02SG-A1A2000000 136H8891 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H8891 and type code NXA13005-A0T02SG-A1A2000000+ARFIFF02V123+DLES is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A2B50000 136H8741 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H8741 and type code NXA04605-A0T02SG-A1A2B50000 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1A2000000 136H8740 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 136H8740 and type code NXA11505-A0T02SG-A1A2000000 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • Next