VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137G2617

VACON 

NXA11505-A0T02SG-A1A2B1D2EA 137G2617 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2617 and type code NXA11505-A0T02SG-A1A2B1D2EA is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137G2489

VACON 

NXA04605-A0T02SG-A1A2D7B5E9 137G2489 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2489 and type code NXA04605-A0T02SG-A1A2D7B5E9+FL23+ARFIFF05+GSNT+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137G2485

VACON 

NXA02055-A0T02SG-A1A200E900 137G2485 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2485 and type code NXA02055-A0T02SG-A1A200E900+FL23+ARFIFF05+DLDE is a 138 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137G2448

VACON 

NXA01685-A0T02SG-A1A2D700E6 137G2448 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2448 and type code NXA01685-A0T02SG-A1A2D700E6+GRID+ARFIF106 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137G2336

VACON 

NXA04605-A0T02SG-A1A200D2E9 137G2336 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2336 and type code NXA04605-A0T02SG-A1A200D2E9 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137G2335

VACON 

NXA02615-A0T02SG-A1A200D2E9 137G2335 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2335 and type code NXA02615-A0T02SG-A1A200D2E9 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137G2295

VACON 

NXA02615-A0T02SG-A1B5D7E9D2 137G2295 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2295 and type code NXA02615-A0T02SG-A1B5D7E9D2+GSNT+SPXE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137G2116

VACON 

NXA02615-G0T02SG-A1A2B50000 137G2116 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2116 and type code NXA02615-G0T02SG-A1A2B50000+GSNT+SPXE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Rectifier Unit 137G2174

VACON 

NXN06506-X0T0NSV-0000000000 137G2174 – VACON NXP Common DC Bus Rectifier Unit, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 137G2174 and type code NXN06506-X0T0NSV-0000000000+EMAR is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus Brake Chopper Unit 137G2114

VACON 

NXB02055-A0T08SG-A1A20000E9 137G2114 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137G2114 and type code NXB02055-A0T08SG-A1A20000E9+DLFR is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137G1953

VACON 

NXA11505-A0T02OG-A1A2000000 137G1953 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G1953 and type code NXA11505-A0T02OG-A1A2000000 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137G1594

VACON 

NXA03256-A0T02SG-A1A2000000 137G1594 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G1594 and type code NXA03256-A0T02SG-A1A2000000+FL23+GSNT+DLDE+LPC2+SPXE is a 377 kW, three-phase 525-690 V supply, IP00...