VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137G3973

VACON 

NXA02615-A0T02SG-A1A2000000 137G3973 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3973 and type code NXA02615-A0T02SG-A1A2000000+FL26+DLCN is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137G3862

VACON 

NXA03256-A0T02SG-A1A2D70000 137G3862 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3862 and type code NXA03256-A0T02SG-A1A2D70000+GRID+ARFIF106+DLIT is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137G3807

VACON 

NXA04605-A0T02SG-A1A2D7E900 137G3807 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3807 and type code NXA04605-A0T02SG-A1A2D7E900+GRID+ARFIF106 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137G3389

VACON 

NXA04605-A0T02SG-A8A20000E9 137G3389 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3389 and type code NXA04605-A0T02SG-A8A20000E9+ARFIFF05+DLFR+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137G3379

VACON 

NXA04605-A0T02SG-A8A20000E9 137G3379 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3379 and type code NXA04605-A0T02SG-A8A20000E9+ARFIFF05+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137G3364

VACON 

NXA02055-A0T02SG-A1A2D7BHE9 137G3364 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3364 and type code NXA02055-A0T02SG-A1A2D7BHE9+GRID+ARFIF106 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137G3344

VACON 

NXB00725-A2T08SV-A1A30000E9 137G3344 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 137G3344 and type code NXB00725-A2T08SV-A1A30000E9+DNOT is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 137G3343

VACON 

NXB01405-A2T08SV-A1A30000E9 137G3343 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 137G3343 and type code NXB01405-A2T08SV-A1A30000E9+DNOT is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus Active Front End Unit 137G3309

VACON 

NXA01706-A0T02SG-A8B1B500E9 137G3309 – VACON NXP Common DC Bus Active Front End Unit, 197 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3309 and type code NXA01706-A0T02SG-A8B1B500E9+ARFIFF05+GSNT+LPC2+SPXE is a 197 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137G3063

VACON 

NXA01706-A0T02SG-A1A20000E9 137G3063 – VACON NXP Common DC Bus Active Front End Unit, 197 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G3063 and type code NXA01706-A0T02SG-A1A20000E9+ARFIFF03 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137G2985

VACON 

NXB02055-A0T08SG-A1A20000E9 137G2985 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137G2985 and type code NXB02055-A0T08SG-A1A20000E9+GSNT+DLFR+LPC2+SPXE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137G2646

VACON 

NXA03855-A0T02SG-A1A2B50000 137G2646 – VACON NXP Common DC Bus Active Front End Unit, 259 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137G2646 and type code NXA03855-A0T02SG-A1A2B50000 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
  • Previous
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • Next